HAR—生物接触氧化处理生活污水
收稿日期: 2005-02-20
网络出版日期: 2010-10-01
基金资助
十五科技攻关资助项目(2003BA808A17)
Application of HAR-biological contact oxidation process to the treatment of domestic sewage
Received date: 2005-02-20
Online published: 2010-10-01
蒋柱武, 罗琳, 赵建夫 . HAR—生物接触氧化处理生活污水[J]. 工业水处理, 2005 , 25(7) : 23 -25 . DOI: 10.11894/1005-829x.2005.25(7).23
Hybrid anaerobic reactor(HAR), followed by biological contact oxidation(BC) technique, is used for treating domestic sewage. When HAR is under operation for 31 d and the water temperature is 15℃, the COD removal rate is up to over 60%. When outlet water is treated by biological contact oxidation, HRT is 3.2 h, the COD of outlet water is less than 40 mg/L averagely, SS less than 12 mg/L, BOD5 and NH3 less than 15 mg/L. The results show that HAR and BC techniques can be used for treating domestic sewage in areas where the climate is suitable.
[1] Alaerts G J, et al.Feasibility of anaerobic sewage treatment in sanitation strategies in developing countries[J].Wat.&Sci.Tech., 1993, 27:179-186
[2] Kalker T J J, et al.Transfer and acceptance of UASB technology for domestic wastewater:two case studies[J].Wat.&Sci.Tech., 1999, 39(5):219-255
[3] Lettinga G, et al.Challenge of psychrophilic anaerobic wastewater treatment[J].Trends in Biotech., 2001, 19(9):363-370
[4] 贺延龄.废水的厌氧生物处理[M].北京:中国轻工业出版社, 1998.1-3
/
〈 | 〉 |