摘要

针对大庆地区气井采出水的水质特征,研制开发出一种新型的处理设备,该设备由混凝破乳、气浮分离、厌氧生物水解和好氧生物氧化多个处理单元组成。利用该设备对大庆油田某气井站进行了2个多月的现场处理试验研究。在进水COD质量浓度2300~51050mg/L、BOD质量浓度1290~7379mg/L,时该装置COD和BOD的平均去除率分别达到96.68%和99.77%,出水COD质量为49~372mg/L,BOD质量浓度为1.6~12.8mg/L。该装置对氨氮、硫化物和SS平均去除率也分别达到95%、99.6%和84.97%。

本文引用格式

季民, 王坚, 张绪强, 王德金, 孙云峰, 晁萌 . 气井采出水综合处理装置的生产性试验研究[J]. 工业水处理, 2005 , 25(3) : 32 -36 . DOI: 10.11894/1005-829x.2005.25(3).32

Abstract

A kind of innovative integrated equipment for treating gas-field wastewater has been developed. 1'lle equipment is composed of a series of units including coagulation,flotation,biological anaerobic hydrolysis and aerobic oxidation. e equipment has been used in agas-field wastewater treatment in Daqing for over two months. The ranges of COD and BOD in the influent during the full scale experiment are 2 3oo一51 050 ms/L and 1 290— 7379 mg/L.respectively. e removals of COD and BOD of the equipment achieve 96.68% an d 99.77% efluent COD an d BOD ran ge are 49-372 ms/L and 1.6—12.8 m Moreover,the removals of ammonia-nitrogen,sulfide and suspended solid achieve 95%,99.6% and 84.97%,respectively.

参考文献

[1] 席建,张庆鸿.吹脱-臭氧化处理气田水[J].天然气工业,1994,14(2):73-76.
[2] 叶燕.内电解法脱除气田水中COD的研究[J].石油与天然气化工,2001,30(1):50-52.
[3] 蒋珍菊,等.凝析沉降-微电解-氧化-吸附法处理高COD.气田水[J].天然气工业,2002,22(2):86-89.
[4] 万里平,等.氧化-吸附法联合处理气田水[J].西南石油学院学报,2003,25(2):55-57.
[5] Cynthia Murrary-Gulde, et al. Performance of a hybrid reverse osmosis-constructed wetland treatment system for brackish oil field produced water[J]. Water Research, 2002, 37(3):705-713.
[6] Campos J C, et al. Oilfield wastewater treatment by combined microfiltration and biological processes[J]. Water Research, 2002,36(1):95-104.
[7] 季民,等.移动床生物膜反应器在污水处理中应用[J].城市环境与城市生态,2000,13(3):47-50.
[8] 郑俊,吴浩汀,程寒飞.曝气生物滤池污水处理新技术及工程实例[M].北京:化学工业出版社,2002.26-38

文章导航

/