甲醛生产中循环冷却水化学处理的研究
网络出版日期: 2010-10-01
Study on chemical treatment of circulating cooling water for production of formaldehyde
Online published: 2010-10-01
彭荣华, 杨明平, 黄念东, 谭翠娥 . 甲醛生产中循环冷却水化学处理的研究[J]. 工业水处理, 2004 , 24(6) : 35 -38 . DOI: 10.11894/1005-829x.2004.24(6).35
Through the selection of 3 kinds of organic corrosion and scale inhibitors, and 3 kinds of biocide, the corrosion and scale problems of formaldehyde circulating water system treated with chemical method are studied. The production practice shows that it not only obtains obvious effect in the aspect of corrosion and scale inhibition, but also reduces the water consumption greatly through the technological conditions, which mix rate of organic composite water treatment chemicals of TS 609 to HEDP is 1 ∶ 2 and sodium dichloroisocyanurate to JN 2 is 1 ∶ 1, concentrating times is 3.5, QM to QR is 8.3%, QB to QR is 6.3%, all concentration of corrosion and scale inhibitor in water is 12 mg/L and so on, are adopted in circulating cooling water system of formaldehyde process.
[l] 龙荷云. 循环冷却水处理[M]. 南京: 江苏科学技术出版社, 1984. 219-230
[2] 杨德红, 严莲荷, 叶静娴. 杀菌剂性能的评价[J]. 科研与开发, 2000, 27(2):22-23
/
〈 | 〉 |