电厂灰水再循环回水水质影响因素的试验研究
收稿日期: 2003-04-17
网络出版日期: 2010-10-01
Experimental study of the influence on the backwater quality in therecycling system of ash water in thermal power plants
Received date: 2003-04-17
Online published: 2010-10-01
吴三毛, 徐锐, 吴平, 张昕宇 . 电厂灰水再循环回水水质影响因素的试验研究[J]. 工业水处理, 2004 , 24(2) : 36 -39 . DOI: 10.11894/1005-829x.2004.24(2).36
This thesis introduces the experimental study of the influence factors on the backwater quality of recycling system of ash water in thermal plants by selected fly ash samples from thermal power plants in Jiangxi Province. The factors includes the component of ash, the ratio of ash to water, the ratio of backwater, the remaining time of ash water in ash field, the raw rushing ash water quality and the stirring time. The experimental result expresses: the main influence factors on the backwater quality is the fly ash component, the next influence factors are the ratio of ash to water, the ratio of backwater and the remaining time of the ash water in the ash field. But the rushing ash water quality and the stirring time on the backwater do not have much influence on it.
Key words: ash water; recycling system; backwater quality; influence factors
[1]朱琴英,肖萍.灰水再循环系统回水水质分类的探讨[J].电力环境保护,1994,10(1):1-14
[2]黄种买,徐奕富.火电厂冲灰水闭路循环技术研究[J].武汉水利电力大学学报.1998,31(3):89-93
[3]赵晓利.灰场回收水垢趋势的判断及防垢措施[J].河北电力技术,2003,22(1):46-49
/
〈 | 〉 |