介绍了临涣煤矸石热电厂自调试以来机械过滤器出水水质恶化的现象,分析了出水水质恶化的原因,提出了相应的处理对策。

本文引用格式

黄校春, 胡群 . 机械过滤器出水水质恶化分析及对策[J]. 工业水处理, 2001 , 21(8) : 36 -37 . DOI: 10.11894/1005-829x.2001.21(8).36

Abstract

The phenomenon of the water quality deterioration in mechanical filter output, since Linhuan Gangue Heat and Power Plant has undergone the test,is introduced.The causes for the water quality deterioration in the mechanical filter output are analyzed and the countermeasures of it are put forward.