分析与监测

荧光分光光度法测定船舶机舱污水中的油

展开
  • 南通市环境保护监测站, 江苏 南通 226006
张丹丹, 1965 年生, 1987 年毕业于南京理工大学环境监测专业, 工程师。电话: 0513- 5516050。

收稿日期: 2000-01-15

  网络出版日期: 2010-10-01

Determination of oil in wastewater in boat's engine room by fluorescence spectrophotometer

Expand
  • Nantong Environmental Monitoring Station, Nantong 226006, China

Received date: 2000-01-15

  Online published: 2010-10-01

摘要

叙述了用荧光分光光度法测定船舶机舱废水中油的最佳实验条件和方法,通过研究几种机舱污油的荧光光谱图,选择了最大激发波长310 nm,发射波长365 nm,该法工作曲线线性范围为0.005~10.0 mg/L,样品实测时标准偏差S=0.002~1.03,变异系数<5%,加标回收率94%~106%。

本文引用格式

张丹丹 . 荧光分光光度法测定船舶机舱污水中的油[J]. 工业水处理, 2000 , 20(5) : 35 -36 . DOI: 10.11894/1005-829x.2000.20(5).35

Abstract

Abstract:The best experimental condition and method that determine oil in wastewater in boat's engine room by fluorescence spectrophotometer is reported. Based on the study of several kinds of fluorescence diagrams of oil in boat's engine room,the λexMAX=310 nm,λemMAX=365 nm are chosen.Its operation curve has the linear range of 0.005~10.0 mg/L; the sample has a standard deviation of 0.002~1.03,CV<5%,and recovery rate of 94%~106%.