循环冷却水系统节水试验及改造方案
收稿日期: 2001-11-12
网络出版日期: 2010-10-01
Experiment of saving water and reforming scheme of the circulating cooling water system
Received date: 2001-11-12
Online published: 2010-10-01
于万波 , 蒋彬 , 魏美娜 . 循环冷却水系统节水试验及改造方案[J]. 工业水处理, 2002 , 22(3) : 40 -44 . DOI: 10.11894/1005-829x.2002.22(3).40
This paper introduces the present running situation of the circulating cooling water in the Ammonia Plant of Dahua Group and the conditions of fresh water provided and saved in Dalian.Now we use the technologies of the desalination of the ED,getting rid of the suspending materials with the highly efficient surface membrane filter and killing the bacteria of ozone to reform circulating cooling water system of the ammonia plant.The destinations of increasing the profit,decreasing the sewage and saving the fresh water have been realized.
[1] 张立红,于满春,等.大化集团合成氨厂水质稳定剂的研制和应用[J].工业水处理,2000,20(8):40—43.
[2] 梅赛尔集团威德公司.联合臭氧和水质稳定剂处理循环冷却水[J].工业水处理,1999,19(1):29—32.
/
〈 |
|
〉 |