分析与监测

浅议废水处理中pH的测量问题

展开
  • 洛阳有色金属加工设计研究院 河南洛阳 471039
周刚(1969- ),1991年毕业于哈尔滨建筑工程学院,工程师

收稿日期: 2001-07-24

  网络出版日期: 2010-10-01

Measuring problems of pH value in wastewater treatment

Expand
  • Luoyang Engineering and Research Institute for Nonferrous Metals Processing, Luoyang 471039, China

Received date: 2001-07-24

  Online published: 2010-10-01

摘要

废水的 pH值是废水处理中的一个重要参数,测量方法正确与否对该值影响很大。介绍了pH计的测量原理,并结合在具体工程设计中的体会,分析了不同处理方式下pH计的设置位置和设置方法,以及设计中应考虑的影响因素。

关键词: pH值; 废水处理; 测量; 设计

本文引用格式

周刚 . 浅议废水处理中pH的测量问题[J]. 工业水处理, 2002 , 22(3) : 46 -48 . DOI: 10.11894/1005-829x.2002.22(3).46

Abstract

The pH value of wastewater is an important parameter for wastewater treatment.It will create a great effect on pH value by using right measuring methods.The measuring principle for pH meter,combined with a specific experience in the design of the engineering is introduced simply.The set locations and set methods in different treating modes,together with the affecting factors which should be taken into account in design are analysed.

参考文献

[1] 侯传嘉,张燕群.pH 测量[M].北京:中国计量出版社,1993:93—97 ;103—110.
[2] 张自杰,钱易,章非娟.环境工程手册———水污染防治卷[M].北京:高等教育出版社,1996:265—266.
[3] 帕特森J W.工业废水处理技术手册[M].北京:化学工业出版社,1993:4—7.