吴潮汉, 徐军, 潘宏南, 唐逸衡, 李本高, 余正齐, 李亚红 . 炼油厂外排污水直接回用于循环水工业运行[J]. 工业水处理, 2002 , 22(8) : 60 -62 . DOI: 11894/1005-829x.2002.22(8).60
Discharged effluent from refineries is reused in circulating cooling water systems by using water treatment techniques,such as RP-12 and RP-78, etc. After an eleven-month industrial test, the results show that the average rates of corrosion are less than 0.052 mm/a,that of scale deposition less than 6.5 mcm,and the average number of bacteria less than 1.2×105mL-1. These results are similar to those of using new water as make up water. The reusing of effluent has not only notable social benefits in saving new water and decreasing the effluent discharge,but has economic benefit for the enterprise which reuses the effluent.
/
〈 | 〉 |