分析与监测

电镀废水中总氰化物测定的新方法

展开
  • 1. 福龙五金电业有限公司, 广东番禺 511483;
    2. 广州市番禺区环境监测站, 广东番禺 511400
丘山(1973- ), 1996 年毕业于南昌航空工业学院化工系工业分析专业, 技术部副主任。联系电话:020-84738683

收稿日期: 2002-04-07

  网络出版日期: 2010-10-01

New method for total cyanide determination in electroplating wastewater

Expand
  • 1. Fulong Hardware Electronic Ind. Co.,Ltd., Panyu 511483, China;
    2. Panyu Environmental Monitoring Station, Panyu 511400, China

Received date: 2002-04-07

  Online published: 2010-10-01

摘要

研究了用丘氏气提定氰器测定电镀废水中总氰化物的条件和方法。实验结果表明,与蒸馏法相比,该法简便安全、分析准确可靠、节电 90 %以上。

本文引用格式

丘山, 丘星初, 刘经才 . 电镀废水中总氰化物测定的新方法[J]. 工业水处理, 2002 , 22(11) : 39 -40 . DOI: 10.11894/1005-829x.2002.22(11).39

Abstract

The condition and method for determining the total cyanide in electroplating wastew ater with Qiu's cyanide extractor are studied.The results show that the method is simpler, safer and more accurate,compared with distillating method.Furthemore, more than 90 % of elect ricity is saved by this method.

参考文献

[1] 国家环保局.水和废水监测分析方法[M].第3版.北京:中国环境科学出版社,1989:305-316.
[2] 丘山.丘氏气提定氰器[P].ZL97 203 908.2,1998.
[3] 丘星初.化学分析手册[M].北京:化学工业出版社,1960:76.