试验研究

滤料表面电位对滤床过滤效果的影响

展开
  • 哈尔滨工业大学市政环境工程学院, 黑龙 江哈尔滨 150090
盛力(1971- ),哈尔滨工业大学博士,研究方向为给水处理除污染技术.电话:(0451)6282820.

收稿日期: 2002-06-15

  网络出版日期: 2010-10-01

基金资助

国家自然科学基金资助项目 :编号 5 982 5 10 6

Influence of the surface potential of filter media on the filtration effect of filtrating beds

Expand
  • School of Municipal and Environmental Engineering, Harbin University of Technology, Harbin 150090, China

Received date: 2002-06-15

  Online published: 2010-10-01

摘要

滤床过滤工艺广泛应用于水处理领域,滤料表面电位对水中悬浮颗粒的过滤去除有很大的影响。石英砂滤料表面带较高的负电位,一些情况下不利于悬浮颗粒的去除。对石英砂、氧化铁改性滤料、复合改性滤料的表面电位和过滤效果的对比表明,复合改性滤料表面电位接近于中性,对水中的悬浮颗粒有稳定良好的去除效果。

本文引用格式

盛力, 马军 . 滤料表面电位对滤床过滤效果的影响[J]. 工业水处理, 2002 , 22(12) : 34 -36 . DOI: 10.11894/1005-829x.2002.22(12).34

Abstract

Filtrating process is used widely in water treatment.Deep bed filtrating effect is influenced by surface potential of filter media greatly.Quartz sand has a much negative surface potential which impact on its effect.The contrasts of surface potentials and filtrating effect of quartz sand,iron oxide coated sand and compound coated sand show that the compound coated sand has a steady and favorable filtrating effect attribute to its near neutral surface potential.

参考文献

[1] Chihpin Huang, Ji ll Rushing Pan, Shuhui Huang.Collision Efficiencies of Algae and Kaolin in Depth Filter :The Effect of Surface Properties of Particles[J].Wat.Res., 1999, 33(5):1 278—1 286.
[2] Chares R, et al.Particles, Pretreatment, and Performance in Water Filtration[J].J.of Environmental Engineering, 1985, 111(6):874—891.
[3] Rajagopalan R, Tien C.Trajectory Analysis of Deep-bed Filtration with the Sphere-in-cell Porous Media Model[J].AIChE J., 1989, 85(22): 523—533.
[4] Mark M, et al.Sorption and Filtration of Metals Using Iron-Oxide-Coated Sand[J].Wat.Res., 1996, 30(11):2 609—2 620.
[5] Sanjeev Bajpai, et al.Removal of Arsenic from Ground Water by Manganese Dioxide-Coated Sand[J].J.Environ.Eng., 1999, 125 (8):782—784.
[6] Chang Yujung, et al.Iron Oxide-CoatedMedia for NOM Sorption and Particulate Fi lt ration[J].J.AWWA., 1997, 89(5):100—113.
[7] Prasad V S, et al.Removal of Bacteria and Turbidity from Water by Chemical Treated Manganese and Iron Ores[J].Aqua., 1995, 44(2): 80—82.
[8] Stenkamp V, et al.Eff ect of Iron Oxide Coating on Sand Filtration[J].J.AWWA., 1994, 86(8):37—50.