Selection of the formula of circulating water treatment in cold rolling thin plate production and its application
Received date: 2005-06-16
Online published: 2010-10-01
Aiming at the water quality conditions of circulating cooling water and its characteristics in cold rolling thin plate production, and through scaling test, corrosion test and dynamic simulating test, the corrosion and scale inhibitors are selected. After one year’s application, the results showthat the selected formula has very good scale and corrosion inhibiting performances.
Key words: circulating coolingwater; scale inhibition; corrosion inhibition
Zhang Huixin, Jin Xiuhong, Sun Wennuan, Gu Zhanchang . Selection of the formula of circulating water treatment in cold rolling thin plate production and its application[J]. Industrial Water Treatment, 2005 , 25(11) : 55 -56 . DOI: 10.11894/1005-829x.2005.25(11).55
[1] 周本省. 工业水处理技术[M] . 北京: 化学工业出版社, 1997. 40- 50
[2] 齐冬子. 敞开式循环冷却水系统的化学处理[M] . 北京: 化学工业出版社, 2001. 87-111
[3] 祁鲁梁, 等. 水处理工艺与运行管理实用手册[M] . 北京: 中国石化出版社, 2002. 118-191
/
〈 | 〉 |