RSM优化SCWO处理高浓度氨氮化肥废水的研究
Research on the RSM optimized SCWO method for the treatment of waste-water containing highly concentrated ammonia nitrogen chemical fertilizer
收稿日期: 2019-02-27
基金资助: |
|
Received: 2019-02-27
Fund supported: |
|
作者简介 About authors
郑烨(1980-),硕士,讲师电话:13511559747,E-mail:
针对化肥废水难生物降解的特性,采用超临界水氧化(SCWO)法对其进行处理。通过响应面法(RSM)对影响处理效果的各因素进行了研究,建立了NH3-N去除率的二次回归模型,优化了处理条件。结果表明,各因素对NH3-N去除率影响的显著性依次为温度>过氧比>压力>反应时间。在优化条件下,NH3-N去除率预测值为97.11%。对比实测值与模型预测值,二者偏差介于-3.88%~2.14%,采用该模型预测值代替实验值进行分析具有较高的可信度。
关键词:
Aiming at the refractory biodegradation characteristic of chemical fertilizer wastewater, supercritical water oxidation(SCWO) method has been used for its treatment. Every factor that affects the treatment effects has been investigated by response surface method(RSM), the quadratic regression model of NH3-N removing rate established, and the treatment condition optimized. The results show that the sequence of all the factors that have significant influence on NH3-N removing rates are temperature > peroxide ratio > pressure > reaction time. Under optimized conditions, the predicted value of NH3-N removing rate is 97.11%. Comparing the measured value with predicted value, it is found that the deviation of them is between -3.88% to 2.14%. The analysis using the predicted value of the model instead of using measured value has higher reliability.
Keywords:
本文引用格式
郑烨, 陈淼超.
Zheng Ye.
超临界水氧化(SCWO)法是近年来迅速发展起来的一种适用于去除各种难降解有毒有害物质的新型水热氧化技术。SCWO法的核心是利用超临界水有别于常态水的独特性质。在超临界条件下,气液相界面消失,异相间传质、传热阻力消失,形成的均相氧化体系促使反应速率显著增大,在极其短暂停留时间内,将有机物氧化生成无二次污染的小分子物质,如N2、H2O、CO2等〔3〕。
1 材料与方法
1.1 实验材料
实验废水:本实验所用废水为安徽省某化肥厂排放废水,水样外观呈无色,有氨味,氨氮为796 mg/L,pH为9.4,COD为240 mg/L。
氧化剂:常温下的自然空气。根据氧气/空气的体积比及密度,计算过氧比。采用气体流量计(DT-LWGQ,多特自动化仪表有限公司)调节进气量;采用高压计量泵(J-X100/2.0,温州荣达泵阀有限公司)调节进液流量,流量为0~2 L/h,压力为0~50 MPa。
1.2 实验装置及流程
采用1套连续式的SCWO设备进行实验,设备实物如图1所示。
图1
实验开始时,废液通过高压计量泵泵入设备内。预热器的加热方式为电加热(加热功率2.5 kW),通过加热高压管盘使预热器快速升温,达到实验设定的温度要求。利用Pt100温度传感器(控温精度± 0.1℃)和温度控制仪控制反应器、预热器及高压悬液分离器的温度。SCWO装置共有2个反应容器(有效容积5.5 L/个,压力0~40 MPa,温度0~650 ℃),反应器材质为AISI316Ti不锈钢。整套反应体系的压力通过调节高压泵及背压阀来控制。
1.3 分析方法
本实验采用江苏盛奥华环保科技有限公司的6B-50(V9)氨氮快速测定仪分析实验处理前后液相中的氨氮浓度,计算氨氮去除率。
2 结果与分析
2.1 中心复合实验设计
表1 设计因素的编码与水平
因素 | 编码 | 水平 | ||||
-2 | -1 | 0 | 1 | 2 | ||
反应温度/℃ | X1 | 400 | 450 | 500 | 550 | 600 |
反应时间/min | X2 | 2 | 4 | 6 | 8 | 10 |
过氧比 | X3 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 |
压力/MPa | X4 | 22 | 24 | 26 | 28 | 30 |
表2 响应面实验结果
实验序号 | X1 | X2 | X3 | X4 | Y/% | |
实验 | 预测值 | |||||
1 | 1 | 1 | 1 | 1 | 96.77 | 96.57 |
2 | 0 | 0 | 0 | 2 | 94.73 | 94.42 |
3 | -1 | -1 | -1 | 0 | 87.77 | 89.50 |
4 | 0 | 0 | 0 | 1 | 95.06 | 95.24 |
5 | 1 | 1 | -1 | 1 | 96.94 | 96.79 |
6 | 0 | -2 | 0 | 0 | 92.14 | 93.90 |
7 | 1 | 1 | 1 | -1 | 96.07 | 96.79 |
8 | 0 | 0 | 0 | 0 | 95.57 | 95.18 |
9 | -1 | -1 | -1 | 1 | 88.68 | 90.17 |
10 | -1 | 1 | -1 | 1 | 93.17 | 90.35 |
11 | 2 | 0 | 0 | 0 | 96.88 | 96.84 |
12 | 0 | 0 | 0 | 0 | 93.83 | 95.18 |
13 | 1 | 1 | -1 | -1 | 95.18 | 95.33 |
14 | 0 | 0 | 0 | 0 | 95.87 | 95.18 |
15 | 1 | 1 | 1 | -1 | 96.57 | 96.79 |
16 | 0 | 2 | 0 | 0 | 95.90 | 95.18 |
17 | 0 | 0 | 2 | 0 | 94.40 | 96.14 |
18 | 1 | -1 | -1 | -1 | 94.06 | 94.03 |
19 | -1 | 1 | 1 | 1 | 92.84 | 92.77 |
20 | -1 | 1 | 1 | -1 | 92.35 | 92.99 |
21 | 0 | 0 | -2 | 0 | 92.27 | 92.06 |
22 | 0 | 0 | 0 | 0 | 95.46 | 95.18 |
23 | -2 | 0 | 0 | 0 | 86.77 | 86.96 |
24 | 0 | 0 | 0 | 0 | 95.29 | 95.18 |
25 | 0 | 0 | 0 | -2 | 94.16 | 92.42 |
26 | -1 | -1 | 1 | 1 | 90.86 | 92.79 |
27 | 1 | -1 | 1 | 1 | 96.39 | 96.23 |
28 | 1 | -1 | -1 | 1 | 95.74 | 96.25 |
29 | -1 | 1 | -1 | -1 | 92.77 | 88.89 |
30 | -1 | -1 | 1 | -1 | 90.11 | 92.25 |
2.2 模型建立与显著性分析
对模型的各项回归系数进行显著性检验和方差分析,结果见表3。
表3 响应值为NH3-N的回归模型方差分析结果
方差来源 | 平方和 | 自由度 | 均方 | F值 | P值>F | 显著性 |
模型 | 212.27 | 14 | 15.16 | 49.75 | < 0.000 1 | 高度显著 |
X1 | 146.77 | 1 | 146.77 | 481.56 | < 0.000 1 | 高度显著 |
X2 | 24.87 | 1 | 24.87 | 81.59 | < 0.000 1 | 高度显者 |
X3 | 5.91 | 1 | 5.91 | 19.39 | 0.000 5 | 显著 |
X4 | 2.44 | 1 | 2.44 | 8.00 | 0.012 8 | 显著 |
X1X2 | 6.90 | 1 | 6.90 | 22.65 | 0.000 3 | 显著 |
X1X4 | 0.12 | 1 | 0.12 | 0.41 | 0.533 4 | 不显著 |
X2X3 | 2.81 | 1 | 2.81 | 9.23 | 0.008 4 | 显著 |
X2X4 | 0.041 | 1 | 0.041 | 0.13 | 0.719 3 | 不显著 |
X3X4 | 0.56 | 1 | 0.56 | 1.83 | 0.196 5 | 不显著 |
X12 | 18.53 | 1 | 18.53 | 60.81 | < 0.000 1 | 高度显著 |
X22 | 2.02 | 1 | 2.01 | 6.60 | 0.021 2 | 显著 |
X32 | 5.36 | 1 | 5.36 | 17.58 | 0.000 8 | 显著 |
X42 | 0.75 | 1 | 0.74 | 2.43 | 0.138 3 | 不显著 |
残差 | 4.59 | 15 | 0.30 | |||
失拟项 | 2.03 | 10 | 0.20 | 0.40 | 0.899 6 | 不显著 |
纯误差 | 2.56 | 5 | 0.51 | |||
总差 | 217.01 | 29 |
另外,根据表3可知,影响因素中交互项X1X2和X2X3对NH3-N去除率影响显著。根据多元二次项模型中的X1~X4系数值,可得出各因素影响响应值的显著性由强到弱依次为反应温度>过氧比>压力>反应时间,表明当控制其他因素在中心水平时,升高温度和增大过氧比较有利于增大NH3-N的去除率。
2.3 响应面图分析
2.3.1 反应温度和反应时间对NH3-N去除率的影响
图2反映了反应时间和反应温度交互作用对NH3-N去除率的影响。
图2
由图2可以看出,这2种因素之间的交互作用对响应值的影响具有较高的显著性,表明控制其他因素为中心水平时,同时改变反应时间和反应温度,能显著改变NH3-N去除率。其中,反应温度对NH3-N去除率的影响较反应时间显著,表现为NH3-N去除率响应面曲线随温度的升高发生较陡的变化。这种情况的发生可能有两方面原因:一方面反应速率随温度的升高而增大,进而可有效提高反应进程;另一方面,在氧浓度充足的条件下,温度升高,反应容器中会产生大量的自由基参与反应,同样会大大推动反应的进程,显著提高NH3-N去除率。另外,反应时间对响应值的影响也具有较高的显著性,即通过延长反应时间亦可有效提高NH3-N去除率。尽管升高温度比延长反应时间对响应值的影响更为显著,但在实际应用中,考虑到能耗方面的要求,在保证污染物有效去除的情况下,需重点考虑反应温度和反应时间之间的交互作用。
2.3.2 反应时间和过氧比对NH3-N去除率的影响
图3反映了反应时间与过氧比交互作用对NH3-N去除率的影响。
图3
2.3.3 较优条件的选取
由于SCWO反应条件相对比较苛刻,对装置设备的材质有严格的要求,因此,需在给定的实验约束条件下,寻找一种最佳的工艺参数,使设备在稳定运行的情况下,既保证污染物的高效去除,同时又尽可能地降低设备的运行能耗。利用RSM对设定的各项影响因素进行优化设计,得到最佳的工艺运行参数:反应温度550 ℃,压力27.17 MPa,反应时间6.21 min,过氧比2.83。在最优条件下,响应值(NH3-N去除率)为97.11%。
2.4 模型的偏差分析
为了验证模型的可靠性,将Y的预测值与实测值进行对比,结果如图4所示。
图4
由图4可看出,NH3-N去除率偏差介于-3.88%~2.14%,说明该模型可信,具有较高的统计学意义。
3 结论
(1)通过响应面法优化选择SCWO处理化肥废水的最优参数,建立了NH3-N去除率的二次多元回归模型。比较模型与实验结果,二者的NH3-N去除率偏差介于-3.88%~2.14%,说明用该模型对实验结果进行分析具有较高的可信度。
(2)模型的各项因子回归系数的显著性检验结果表明,设定的因素对NH3-N去除率的影响顺序依次为反应温度>过氧比>压力>反应时间。其中,反应时间和反应温度的交互作用对NH3-N去除率的影响具有较高的显著性。
(3)利用RSM对设定的各项影响因素进行优化设计,得到最佳的工艺运行参数:反应温度550 ℃,压力27.17 MPa,反应时间6.21 min,过氧比2.83。在最优条件下,响应值(NH3-N去除率)为97.11%。
4 展望
超临界水氧化法作为近些年新兴的一种高级氧化处理技术,应用前景极其广泛,该工艺产物为无二次污染的小分子化合物。超临界条件下,盐类几乎完全分离出来,处理后的出水可达到回用条件。该方法独特的优越性在于其适用于各种常规生化方法难以处理的高浓度高毒害工业废水的处理。然而,尽管SCWO工艺有诸多独特的优越性,但SCWO设备规模化生产却存在一定的瓶颈,究其原因主要是设备腐蚀、反应器积盐及管路堵塞、运行成本相对较高等因素的制约。目前,已有不少专家学者开展了针对性的研究。Chengyu Ma等〔10〕在超临界条件下,研究了十几种镍基合金材料的耐腐蚀情况,以期寻找到合适的设备制造材料。Ziqiang Dong等〔11〕研究了Cr2O3基陶瓷材料的耐腐蚀情况,结果表明,当温度超过临界温度时,由其制备的反应器的腐蚀速率会随温度升高而降低。美国学者M. Svanstrom通过提高管式反应器中流体流速来解决积盐问题,取得了良好的效果〔12〕。美国Sandia实验室建立了一种具有渗透壁的SCWO反应器,大大减轻了设备的沉盐及腐蚀问题。随着对SCWO技术逐步深入地研究、新型催化剂及高性能耐压耐腐蚀材料的研制、工艺方面不断的优化创新,相信SCWO技术将在石化、钢铁、印染、造纸、汽车、电子行业均具有广泛的应用前景。
参考文献
响应面法在污水处理工艺优化中的应用
[J].DOI:10.3969/j.issn.1004-1656.2017.06.001 [本文引用: 1]
Kinetic analysis for ammonia decomposition in supercritical water oxidation of sewage sludge
[J].
Corrosion of some Ni-base alloy stainless steels in chloride solution for supercritical water oxidation process
[J].
Corrosion behavior of chromium oxide based ceramics in supercritical water(SCW) environments
[J].DOI:10.1016/j.corsci.2012.08.048 [本文引用: 1]
超临界水氧化技术应用研究进展
[J].DOI:10.3969/j.issn.1673-4076.2011.11.037 [本文引用: 1]
/
〈 |
|
〉 |