气浮-微电解-Fenton-厌氧/好氧工艺处理制药废水
|
安浩东,黄俊逸,朱乐辉
|
Air flotation-Fe/C microelectrolysis-Fenton-anaerobic-aerobic process for treatment of pharmaceutical wastewater
|
Haodong An,Junyi Huang,Lehui Zhu
|
|
表2 系统各单元运行效果
|
|
|
处理单元 | pH | COD/ (mg·L-1) | NH3-N/ (mg·L-1) | 甲苯/ (mg·L-1) | 调节池1 | 8~9 | 9 256~9 630 | 192~216 | 110.54~126.86 | 气浮池 | 7~9 | 8 320~8 500 | 178~186 | 12.32~15.18 | 微电解池 | 2~4 | 7 124~7 430 | 158~162 | 5.64~8.13 | Fenton池 | 3~4 | 5 752~5 965 | 135~143 | 1.22~1.51 | 调节池2 | 7~9 | 3 350~3 668 | 75~88 | 2.32~2.57 | 混凝沉淀池 | 8~9 | 2 984~3 276 | 70~85 | 2.03~2.16 | 厌氧池 | 6~8 | 1 050~1 390 | 46~53 | 0.75~0.78 | A/O池 | 7~8 | 95~126 | 10~15 | 0.09~0.13 | 生物滤池 | 7~8 | 28~46 | 3~7 | 0.05~0.07 |
|
|
|