类Fenton体系降解间甲酚的研究及其响应面优化
Degradation of m-cresol by Fenton-like system and its response surface optimization
通讯作者:
收稿日期: 2019-09-22
基金资助: |
|
Received: 2019-09-22
Fund supported: |
|
焦化废水中的间甲酚质量浓度可达90 mg/L,为了高效处理工业含酚废水,以间甲酚为目标污染物,采用基于硫酸根自由基的HA/Fe2+/PMS类Fenton体系,考察了各因素对间甲酚降解效能的影响。采用Box-Behnken响应面法优化了反应条件并拟合出回归模型,在反应溶液初始pH=4时,得出最佳反应条件:Fe2+浓度0.5 mmol/L,PMS投加量5 mmol/L,HA浓度2.5 mmol/L,在此优化条件下,间甲酚去除率为92.84%。
关键词:
Since the content of m-cresol in the coking wastewater can reach 90 mg/L, it can be used as the targeted contaminant to investigate the treatment efficiency of industrial wastewater containing phenols. A Fenton-like system of HA/Fe2+/PMS based on sulfate radical was applied to degrade m-cresol. The effects of various factors on the degradation of m-cresol were investigated. The Box-Behnken response surface method was adopted to optimize reaction conditions and fit the regression model. With the initial solution pH of 4, the removal rate of m-cresol reached 92.84% under the optimal conditions, which were found at Fe2+ concentration of 0.5 mmol/L, PMS dosage of 5 mmol/L, and HA concentration of 2.5 mmol/L.
Keywords:
本文引用格式
刘屹, 许昶雯, 王国英.
Liu Yi.
近年来,在处理难降解有机污染物的各种高级氧化技术中,基于硫酸根自由基(SO4·-,E0为2.5~3.1 V)的Fe2+与过一硫酸盐(HSO5-,简称PMS)组成的类Fenton体系,因其具有氧化能力强、操作简单、反应快速等特点而逐渐受到重视〔3〕。然而,pH适用范围较窄,Fe3+向Fe2+循环转化效率较低造成铁泥易累积,氧化剂无法充分利用等缺点限制了该类Fenton体系的实际应用〔4〕。研究表明,羟胺(HA)等还原剂的加入能有效促进Fe2+/PMS类Fenton体系中Fe3+向Fe2+的转化,加速类Fenton体系中硫酸根自由基的生成,进而提高体系的氧化效率〔5〕。为此笔者利用羟胺强化Fe2+/过一硫酸盐体系对高浓度间甲酚1 mmol/L(108 mg/L)的降解进行了研究,并用响应面法(RSM)对实验条件进行了优化。
1 实验部分
1.1 主要试剂与仪器
间甲酚、七水合硫酸亚铁、过一硫酸盐、盐酸羟胺、亚硝酸钠、盐酸、氢氧化钠,均为分析纯;甲醇为分析纯和色谱纯;溶液均采用超纯水配制。
HH数显恒温磁力搅拌水浴锅,常州国宇仪器制造有限公司;pH计,pHS-3C型,上海仪电科学仪器有限公司;高效液相色谱仪,Ultimate 3000型,美国戴安公司。
1.2 实验方法
配制500 mL的间甲酚溶液置于恒温磁力搅拌水浴锅中并保持温度在(25±0.5)℃,在磁力搅拌器的作用下,向反应液中加入一定浓度的HA和Fe2+,随后调节溶液到所需pH,加入一定浓度的PMS启动反应,并在反应的0、1、2、3、5、7、10 min时取样,投加过量甲醇(分析纯)或亚硝酸钠以终止反应,混合均匀后进行分析。
1.3 分析方法
间甲酚浓度用高效液相色谱仪(HPLC)测定,色谱条件:Agilent XDB-C18分析色谱柱(4.6 mm×250 mm,5 μm),流动相V甲醇:V水=60:40,流速1 mL/min,柱温30 ℃,UV检测波长272 nm。
2 结果与讨论
2.1 初始pH对间甲酚降解的影响
为了避免缓冲试剂的加入可能会与HA/Fe2+/PMS反应体系中的Fe2+和Fe3+产生络合作用,所以在考察溶液初始pH影响时采用氢氧化钠和盐酸溶液来调节初始pH〔6〕。固定溶液中Fe2+浓度为0.5 mmol/L,HA和PMS浓度均为10 mmol/L,考察溶液初始pH对HA/Fe2+/PMS体系中间甲酚降解效能的影响,结果显示,溶液初始pH在2~10的范围内,体系内间甲酚的降解效能均较好,去除率在74%以上;当溶液酸碱性较强时,体系的pH在整个反应过程中几乎维持不变,体系内间甲酚的去除率则显著降低至30%左右。需要注意的是,由于本实验中溶液的初始pH是在反应启动前确定,而启动反应时加入的PMS会对溶液pH造成较大影响,结果见表1。
表1 pH对间甲酚去除率的影响
初始pH | 1.5 | 2 | 3 | 4 | 5 | 7 | 10 | 12.5 |
反应30s后pH | 1.5 | 1.96 | 2.36 | 2.40 | 2.45 | 2.47 | 5.50 | 12.40 |
反应结束时pH | 1.4 | 1.67 | 1.79 | 1.82 | 1.83 | 1.85 | 2.38 | 12.30 |
去除率/% | 33.0 | 81.7 | 95.2 | 95.4 | 95.5 | 90.9 | 74.5 | 28.7 |
2.2 铁离子浓度对间甲酚降解的影响
在pH=4.0,HA和PMS浓度均为10 mmol/L的条件下,考察Fe2+浓度对HA/Fe2+/PMS体系降解间甲酚的影响,结果如图1所示。
图1
由图1可知,当Fe2+浓度为0.025 mmol/L时,反应10 min甲酚的去除率即可达到60.2%,这说明在HA/Fe2+/PMS体系中,Fe2+作为促进PMS分解产生SO4·-的活化剂而存在,较低的Fe2+浓度即可使HA/Fe2+/PMS体系持续、快速地降解间甲酚。随着Fe2+浓度的增加,间甲酚的去除率随之增大,当Fe2+浓度从0.025 mmol/L增加到0.25 mmol/L,反应10 min内间甲酚的去除率由60.2%增大到89.4%,继续增大Fe2+浓度至0.5 mmol/L时,间甲酚去除率未见明显增加,这主要是因为过量的亚铁离子会与硫酸根自由基反应,导致部分硫酸根自由基被消耗〔8〕。
2.3 PMS浓度对间甲酚降解的影响
在pH为4.0,Fe2+浓度为0.5 mmol/L,HA浓度为10 mmol/L的条件下,考察不同PMS浓度对HA/Fe2+/PMS体系降解间甲酚的影响,结果如图2所示。
图2
体系中PMS在Fe2+的活化作用下分解产生强氧化性的活性物种SO4·-是间甲酚得以降解的主要原因,所以PMS浓度会直接影响该体系对间甲酚的降解效能。当体系中的PMS浓度由0.5 mmol/L增加到5 mmol/L时,间甲酚的去除率由11.55%增大至93.70%,这主要是因为过量的PMS将部分Fe3+还原成Fe2+,从而增加了该体系的氧化效能〔9〕。继续提高体系中的PMS浓度至10 mmol/L,体系中间甲酚的去除率并无明显增加,可能的原因是,过量的PMS在体系中生成大量的活性物种,与自由基发生湮没反应;另一方面,其将部分氧化能力较强的SO4·-转化成氧化能力相对较弱的SO5·-,从而对该体系的氧化效能产生一定程度的抑制作用。
2.4 HA浓度对间甲酚降解的影响
在pH为4.0,浓度Fe2+为0.5 mmol/L,PMS浓度为5 mmol/L的条件下,考察不同HA浓度对HA/Fe2+/PMS体系降解间甲酚的影响,结果表明,当HA的投加量由0.5 mmol/L增加到2.5 mmol/L时,间甲酚的去除率由44.99%逐渐增大至91.42%,可能的原因是,PMS还原Fe3+生成的Fe2+的速度较慢,难以满足体系中Fe2+的需求量;投加的HA通过反应加快了Fe3+向Fe2+的电子传递,减少了Fe3+的积累,从而促进自由基的生成和该体系的氧化效能。当HA投加量大于2.5 mmol/L时,继续增加HA的投加量至5 mmol/L,体系中间甲酚的去除率几乎没有增大,这是由于在溶液初始pH=4的条件下,溶液中以NH3OH+为主要存在形式的HA与体系中的活性物种(SO4·-)具有较高的反应速率,高浓度的HA可能会消耗部分硫酸根自由基〔5〕,导致间甲酚去除率不再增加。
3 响应面优化实验
3.1 Box-Behnken实验设计
表2 Box-Behnken实验设计的因素与水平
编码水平 | 实验因素及各水平取值 | ||
A(Fe2+浓度)/(mmol·L-1) | B(PMS投加量)/(mmol·L-1) | C(HA浓度)/(mmol·L-1) | |
-1 | 0.025 | 0.5 | 0.5 |
0 | 0.26 | 2.75 | 1.5 |
1 | 0.5 | 5 | 2.5 |
表3 Box-Behnken实验设计及结果
实验号 | 编码水平 | 去除率/% | |||||
A | B | C | 预量值Y1 | 实测值Y2 | |||
1 | 0 | -1 | 1 | 10.23 | 10.47 | ||
2 | 0 | 0 | 0 | 39.64 | 37.01 | ||
3 | 1 | 0 | 1 | 62.76 | 60.88 | ||
4 | 0 | 1 | -1 | 32.23 | 31.99 | ||
5 | 1 | 1 | 0 | 72.52 | 71.25 | ||
6 | 0 | 0 | 0 | 36.8 | 37.01 | ||
7 | -1 | 0 | 1 | 37.76 | 36.24 | ||
8 | 0 | 0 | 0 | 37.93 | 37.01 | ||
9 | 0 | -1 | -1 | 5.34 | 2.19 | ||
10 | 1 | -1 | 0 | 11.56 | 13.19 | ||
11 | -1 | 0 | -1 | 16.76 | 18.63 | ||
12 | -1 | 1 | 0 | 44.65 | 43.02 | ||
13 | 0 | 1 | 1 | 71.12 | 74.27 | ||
14 | 0 | 0 | 0 | 35.13 | 37.01 | ||
15 | -1 | -1 | 0 | 6.21 | 7.48 | ||
16 | 0 | 0 | 0 | 35.54 | 37.01 | ||
17 | 1 | 0 | -1 | 26.41 | 27.93 |
3.2 回归模型的拟合及方差分析
应用Design Expert软件对实验结果进行二次回归拟合并进行ANOV方差分析,得到的编码方程模型:Y=37.01+8.48A+24.40B+12.64C+5.63AB+3.84 AC+8.50BC+1.46A2-4.73B2-2.55C2,方差分析结果见表4。
表4 间甲酚去除率的回归模型方差分析
方差来源 | 平方和 | 自由度 | 均方 | F值 | P值 | 显著性 |
模型 | 6840.44 | 9 | 760.05 | 99.16 | <0.000 1 | 非常显著 |
A | 575.79 | 1 | 575.79 | 75.12 | <0.000 1 | 非常显著 |
B | 4379.54 | 1 | 4 379.54 | 571.37 | <0.000 1 | 非常显著 |
C | 1278.41 | 1 | 1 278.41 | 166.79 | <0.000 1 | 非常显著 |
AB | 126.79 | 1 | 126.79 | 16.54 | 0.004 8 | 非常显著 |
AC | 58.92 | 1 | 58.91 | 7.69 | 0.027 6 | 显著 |
BC | 289 | 1 | 289.00 | 37.70 | 0.000 5 | 非常显著 |
A2 | 8.97 | 1 | 8.97 | 1.17 | 0.315 1 | |
B2 | 94.31 | 1 | 94.31 | 12.30 | 0.009 9 | 非常显著 |
C2 | 27.28 | 1 | 27.28 | 3.56 | 0.101 | 2 |
残差 | 53.65 | 7 | 7.66 | 3.96 | 0.1083 | |
失拟值 | 40.15 | 3 | 13.38 | |||
纯误差 | 13.50 | 4 | 3.38 | |||
总离差 | 6 894.09 | 16 |
注:P < 0.05为显著;P < 0.01为非常显著。
3.3 因素交互作用分析
依据方程模型作出三维曲面图,研究Fe2+浓度、PMS投加量、HA浓度对间甲酚去除率的影响,固定三个因素中的任一因素在中心点水平,研究其他两因素对间甲酚去除率的交互作用,结果表明,PMS和HA的交互作用最为显著,其次是Fe2+和PMS,最后是Fe2+和HA。
3.4 最优条件的预测与分析
依据前述二次多项式模型,经Design Expert8.0分析给出的间甲酚最佳去除条件为:Fe2+浓度0.5 mmol/L,PMS投加量5 mmol/L,HA浓度2.5 mmol/L,在此优化条件下,模型预测的间甲酚去除率为93.67%。为验证模型的准确性与有效性,在优化条件下进行三组平行的验证实验,得到间甲酚去除率的平均值为92.84%,这与模型预测值相接近,误差为0.83%,表明模型可以较为准确地用来预测各因素对间甲酚去除率的影响。
4 结论
(1)基于硫酸根自由基的HA/Fe2+/PMS反应体系在pH为3~5时适用性最好,10 min内间甲酚的去除率可达95%以上。
(2)在一定范围内,HA/Fe2+/PMS体系对目标物间甲酚的去除作用随反应物HA、Fe2+和PMS投加量的增加而增强,但过量的反应物并不会使目标物的去除率持续增加,原因是过量的反应物可能与反应体系中产生的SO4·-发生反应或者体系中过量的自由基本身发生湮没反应。
(3)利用Design Expert8.0软件进行Box-Behn-ken实验设计,对实验结果进行二次拟合得到以间甲酚去除率为响应值的编码方程模型,进行回归分析得到决定系数R2=0.992 2,说明模型拟合度较高,可以利用本模型进行以间甲酚去除率为响应值的分析预测。
(4)模型得到的间甲酚最佳去除条件是:Fe2+浓度0.5 mmol/L,PMS投加量5 mmol/L,HA浓度2.5mmol/L,在此优化条件下,模型预测的间甲酚去除率为93.67%,验证得知预测值与实验值非常接近,表明该模型的实用性和准确性。
参考文献
Advanced oxidation processes for organic contaminant destruction based on the Fenton reaction and related chemistry
[J].DOI:10.1080/10643380500326564 [本文引用: 1]
Rapid acceleration of ferrous iron/peroxymonosulfate oxidation of organic pollutants by promoting Fe(Ⅲ)/Fe(Ⅱ) cycle with hydroxylamine
[J].
Radical generation by the interaction of transition metals with common oxidants
[J].
Degradation of a xanthene dye by Fe(Ⅱ)-mediated activation of Oxone process
[J].
Application of response surface methodology for optimization of azo dye removal by oxalate catalyzed photoelectro-Fenton process using carbon nanotube-PTFE cathode
[J].
/
〈 |
|
〉 |