铁刨花曝气/H2O2体系改善腈纶废水的可生化性研究
Improving the biodegradability of acrylic fiber wastewater by iron scrape aeration/H2O2 system
收稿日期: 2020-07-20
Received: 2020-07-20
在铁刨花曝气体系(Fe0/O2对照体系)中投加活性炭或H2O2构建了Fe0/O2/C体系和Fe0/O2/H2O2体系,考察3种体系对腈纶废水中COD、SCN-的去除效果。结果表明,当废水pH为3.0,H2O2投加量为3 mL/L,铁刨花投加量为75 g/L,曝气量为60 L/h,反应时间为30 min时,COD、SCN-的去除率分别达到70%、98%以上;Fe0/O2/H2O2体系中的COD被优先去除,H2O2对SCN-的去除起到了促进作用,降低了其对微生物的抑制作用,可生化性得到显著改善。曝气作用有利于COD的去除,曝气量过大则气泡黏滞、包裹在铁刨花表面,COD去除率反而下降。
关键词:
Based to the iron scrape aeration system, the iron scrape aeration/C and iron scrape aeration/H2O2 systems were constructed by adding activated carbon or H2O2. The COD and SCN-removal efficiencies of three systems on the acrylic fiber wastewater were investigated. The results showed that when the wastewater was adjusted to pH 3.0, and the reaction conditions were ascertained as H2O2 dosage 3 mL/L, iron scrape about 75 g/L, aeration volume 60 L/h, reaction time 30 min, COD and SCN-removal efficiencies were more than 70% and 98%, respectively. COD in iron scrape aeration/H2O2 system was preferentially removed. H2O2 promoted the removal of SCN- and reduced its inhibition on microorganisms, the biodegradability was significantly improved, the aeration effect was beneficial to the COD removal. When the aeration was too large, the air bubbles were viscous and wrapped on the surface of the iron scraps, and the COD removal efficiency was decrease.
Keywords:
本文引用格式
刘文, 满强强.
Liu Wen.
Fe0/O2体系产生的活性中间体H2O2是形成·OH的重要引发剂〔7〕,本研究采用铁刨花曝气系统与外加活性炭或H2O2联用工艺对腈纶废水进行处理,通过不同反应体系的比选、不同H2O2投加量、铁刨花投加量和曝气量的处理效果分析,确定最佳工艺参数,提高了该废水的可生化性。
1 实验部分
1.1 废水水质和铁刨花
废水源自某石化公司硫氰酸钠溶剂法腈纶生产工艺,其水质指标:COD为610~780 mg/L,SCN-为82~99 mg/L,BOD5为135~160 mg/L,B/C约为0.20,pH为6.0~7.0。
铁刨花取自某校机械加工车间,属中碳钢铁刨花,其含铁量> 95%,含碳量为0.25%~0.65%。使用前先用热碱水洗除油,将铁刨花浸泡在5%Na2CO3溶液中,在恒温(70 ℃)水浴振荡器中振荡60 min;随后取出用去离子水冲洗至中性后,用5 %稀硫酸溶液浸泡60 min活化;最后用去离子水反复冲洗至中性,沥干水分后用烘箱于60 ℃烘干备用。
1.2 实验设计
实验装置见图1。
图1
实验装置由约1.5 L的锥底反应器(装填适量铁刨花)、砂芯曝气板等组成,序批式操作,废水初始pH调至3.0〔8〕。本研究设计3种曝气体系:(1)Fe0/O2对照体系(只装填铁刨花);(2)Fe0/O2/C体系(在填装铁刨花的同时投加活性炭);(3)Fe0/O2/H2O2体系(在填装铁刨花的同时投加30%H2O2)。首先比较3种体系对COD、SCN-的处理效果,在此基础上选取最优工艺考察H2O2投加量、曝气量、铁刨花投加量对3种体系COD、SCN-去除效果的影响。
1.3 测定方法
COD采用HZ-HJ-SZ-0108测定;BOD5采用HJ 505—2009测定;pH采用PHS-3C计测定。SCN-按文献〔9〕的方法测定。
2 结果与讨论
2.1 曝气体系的选择
用稀硫酸调节1 L腈纶废水的pH为3.0,置于锥底反应器中,Fe0/O2对照体系固定铁刨花投加量为75 g/L、曝气量为60 L/h;在此基础上设立活性炭投加量为3 g/L的Fe0/O2/C体系、H2O2投加量为3 mL/L的Fe0/O2/H2O2体系,考察反应时间对COD、SCN-去除效果的影响,结果见图2。
图2
由图2可知,3种曝气体系在15 min内均表现出对COD、SCN-的快速去除效果,整个反应过程在30 min内基本完成。Fe0/O2对照体系的COD去除率为57.1%,SCN-去除率为12.5%,与Fe0/O2/C体系相比,后者的COD、SCN-去除率增幅分别为2.1%、0.9%;而Fe0/O2/H2O2体系由于引入了H2O2,COD、SCN-去除率的增幅明显,最高分别可达15.6%、77.5%。由此可见,由于铁刨花中含有碳元素,因此投加活性炭对COD、SCN-的去除效果影响不大;而酸性条件下导致了铁刨花中Fe2+的溶出,即使是Fe0/O2对照体系也会产生有限的H2O2〔7〕,这是因为由于铁刨花中含有少量的炭,与铁可形成微原电池,微电解效应产生的初生态、具有高化学活性的Fe2+和[H]〔10〕,尽管·OH的产量有限,但仍可参与反应,使废水中有机物发生断链、开环,从而实现有机物的降解。H2O2的投加则强化了系统的Fenton效应,有利于COD、SCN-的去除。3种反应体系在曝气作用下,随着反应时间的延长,易生成Fe3+及铁的水合氧化物〔11〕。反应30 min后,COD的去除率有所降低。故选取Fe0/O2/H2O2体系,反应时间为30 min为后续实验条件。
2.2 H2O2投加量对废水COD、SCN-去除效果的影响
实验条件同上,考察H2O2投加量对COD、SCN-去除效果的影响,同时,以仅投加H2O2(3 mL/L)处理该腈纶废水作为对比实验,结果见图3。
图3
表1 Fe0/O2/H2O2体系中H2O2投加量对废水可生化性的影响
H2O2/(mL·L-1) | COD/(mg·L-1) | SCN-/(mg·L-1) | CODSCN-/(mg·L-1) | COD修正值/(mg·L-1) | BOD5 /(mg·L-1) | B/C | B/C修正值 |
原水 | 766.0 | 96.0 | 102.7 | 663.3 | 153.2 | 0.20 | 0.23 |
0 | 328.6 | 78.2 | 83.7 | 244.9 | 72.3 | 0.22 | 0.30 |
1 | 317.9 | 69.4 | 74.3 | 243.6 | 76.3 | 0.24 | 0.31 |
2 | 288.8 | 46.9 | 50.2 | 238.6 | 78.0 | 0.27 | 0.33 |
3 | 252.1 | 20.7 | 22.2 | 229.9 | 78.1 | 0.31 | 0.34 |
4 | 220.6 | 3.6 | 3.8 | 216.8 | 72.8 | 0.33 | 0.34 |
5 | 208.4 | 1.4 | 1.5 | 206.8 | 72.9 | 0.35 | 0.35 |
由表1可知,原水的B/C为0.20,扣除SCN-的影响,B/C修正值为0.23,该废水的可生化性相对较差。当H2O2投加量为0时(即Fe0/O2对照体系),COD、BOD5主要依靠铁碳微电解作用去除,B/C修正值虽为0.30,但废水中残留SCN-的影响,B/C为0.22,可生化性依然相对较差。H2O2的引入对COD的去除效果影响不大,废水中残留的COD基本维持在230~245 mg/L,而对SCN-的去除效果较为显著,COD去除率的缓慢上升就得益于对SCN-的去除,SCN-的去除降低了其对微生物的抑制作用。当H2O2投加量为3 mL/L时,B/C为0.31,与Fe0/O2对照体系的B/C修正值(0.30)接近,因此可以认为该废水的可生化性得到了明显的改善。
2.3 曝气量的影响
在上述实验的最佳条件下,调节曝气量分别为30、60、90、120、150 L/h,考察曝气量对COD、SCN-去除效果的影响,结果见图4。
图4
由图4可知,随着曝气量的增大,COD去除率呈先升高后下降的趋势;当曝气量分别为60、90 L/h时,COD去除率分别为66.9%、71.2%,反应后的B/C为0.32。这是因为,有氧存在的条件下,铁碳微电解系统的电极电位差提高了1.22 V〔12-13〕,导致原电池反应增多,有利于铁刨花表面反应生成Fe2+,形成Fenton效应,另外曝气也可同时实现铁刨花表面的冲刷,对COD的去除更有利;但曝气量过大时,空气气泡对铁刨花表面存在黏滞、包裹作用,反而降低了废水中污染物与其表面的接触几率,Fe2+的溶出受到了抑制,减缓了微电解作用和Fenton效应,COD的去除率反而随曝气量的增大而下降。当曝气量分别为60、90 L/h时,SCN-的去除率分别为91.3%、91.5%,从工程的经济角度出发,综合各项影响因素,曝气量以选取60~90 L/h为宜。
2.4 铁刨花投加量的影响
在上述实验的最佳条件下,调节铁刨花投加量分别为25、50、75、100、150 g/L,考察铁刨花投加量对COD、SCN-去除效果的影响,结果见图5。
图5
由图5可知,随着铁刨花投加量的增加,反应体系中的COD去除率呈现先不断升高随后缓慢下降的趋势,当铁刨花投加量为75 g/L时,COD去除率高达73.4%,反应后B/C升至0.31左右。刘勇健等〔10, 14〕的研究结果表明,酸性条件下,由于铁刨花产生的Fe2+基本能够满足Fenton氧化的需要,可以忽略pH的影响。结合图3结果和相关的文献〔15〕可知,反应体系中SCN-的去除率呈现快速上升后持平的趋势;分析其原因,除了铁碳微电解效应之外,还因为实验中投加的H2O2与铁刨花溶出的Fe2+形成Fenton试剂,在反应初期就对SCN-起到了快速去除的效果,而反应后期由于体系中残留的SCN-过少,铁刨花投加量对其影响不显著。综合考虑各项因素,铁刨花投加量选取75 g/L。
3 结论
(1)与Fe0/O2对照体系、Fe0/O2/C体系相比,Fe0/ O2/H2O2体系对COD、SCN-的去除效果较好,当腈纶废水pH为3.0,H2O2投加量为3 mL/L、铁刨花投加量为75 g/L、曝气量为60 L/h,反应时间为30 min时,废水B/C由0.20上升为0.31,可生化性得到了明显改善。
(2)Fe0/O2/H2O2体系中的COD被优先去除,H2O2对SCN-的去除起到了促进作用。
(3)酸性条件下,曝气作用促进了铁刨花表面溶出Fe2+,而且同时完成对铁刨花表面的冲刷,对COD的去除更有利;但当曝气量过大时,空气气泡对铁刨花表面产生了黏滞、包裹作用,COD去除率反而会下降。
(4)铁刨花的投加直接影响了铁碳微电解效应,过多的铁刨花会提供较多的Fe2+,反而破坏其积极作用。
参考文献
Effect of Fenton-like reactions on the degradation of thiocyanate in water treatment
[J].DOI:10.1016/j.jece.2014.08.010 [本文引用: 1]
A review on acrylic based hydrogels and their applications in wastewater treatment
[J].
Effect of pH on Fenton and Fenton-like oxidation
[J].DOI:10.1080/09593330802468848 [本文引用: 1]
铁元素在铁炭微电解-Fenton试剂深度处理印染废水中的形态及含量变化试验研究
[J].
铁刨花-Fenton-絮凝工艺对染料生产废水中AOX、色度和TOC的去除效果研究
[J].
Rate law of Fe(Ⅱ) oxidation under low O2 conditions
[J].DOI:10.1016/j.gca.2013.06.014 [本文引用: 1]
/
〈 |
|
〉 |