		| 表3 加标回收率和RSD试验测定结果 
 | 
	
		|  | 
	
		|  | 
	
		|    | 元素 | 样品编号 | 加标量/mg | 测定值/mg | 加标回收率/% | RSD/% |   | K | A | 0.50 | 0.51 | 102.00 | 1.31 |   | B | 0.50 | 0.51 | 102.00 | 1.28 |   | C | 0.50 | 0.52 | 104.00 | 1.20 |   | D | 0.50 | 0.52 | 104.00 | 1.18 |   | Na | A | 0.50 | 0.51 | 102.00 | 1.45 |   | B | 0.50 | 0.53 | 106.00 | 1.56 |   | C | 0.50 | 0.55 | 110.00 | 1.63 |   | D | 0.50 | 0.51 | 102.00 | 1.71 |   | Ca | A | 0.50 | 0.51 | 102.00 | 0.57 |   | B | 0.50 | 0.53 | 106.00 | 0.59 |   | C | 0.50 | 0.53 | 106.00 | 0.66 |   | D | 0.50 | 0.52 | 104.00 | 0.71 |   | Mg | A | 0.50 | 0.53 | 106.00 | 0.44 |   | B | 0.50 | 0.52 | 104.00 | 0.47 |   | C | 0.50 | 0.51 | 102.00 | 0.52 |   | D | 0.50 | 0.53 | 106.00 | 0.44 |   | Al | A | 2.00 | 2.10 | 105.00 | 0.86 |   | B | 2.00 | 2.15 | 107.50 | 0.91 |   | C | 2.00 | 2.16 | 108.00 | 0.78 |   | D | 2.00 | 2.18 | 109.00 | 0.84 |   | Fe | A | 5.00 | 5.45 | 109.00 | 1.12 |   | B | 5.00 | 5.42 | 108.40 | 1.37 |   | C | 5.00 | 5.50 | 110.00 | 1.21 |   | D | 5.00 | 5.51 | 110.20 | 1.45 |   | Si | A | 2.00 | 2.17 | 108.50 | 1.07 |   | B | 2.00 | 2.15 | 107.50 | 1.09 |   | C | 2.00 | 2.14 | 107.00 | 1.16 |   | D | 2.00 | 2.10 | 105.00 | 1.20 |   | P | A | 0.50 | 0.54 | 108.00 | 1.29 |   | B | 0.50 | 0.55 | 110.00 | 1.48 |   | C | 0.50 | 0.58 | 116.00 | 1.35 |   | D | 0.50 | 0.56 | 112.00 | 1.30 |  | 
	
		|  | 
	
		|  |