ICP-AES法测定火电厂垢成分实验条件优化研究
顾泽坤,孙钊,星成霞,王应高,胡志光

Optimization of experimental conditions for determination of scale composition in thermal power plant by ICP-AES
Zekun Gu,Zhao Sun,Chengxia Xing,Yinggao Wang,Zhiguang Hu
表3 加标回收率和RSD试验测定结果
元素 样品编号 加标量/mg 测定值/mg 加标回收率/% RSD/%
K A 0.50 0.51 102.00 1.31
B 0.50 0.51 102.00 1.28
C 0.50 0.52 104.00 1.20
D 0.50 0.52 104.00 1.18
Na A 0.50 0.51 102.00 1.45
B 0.50 0.53 106.00 1.56
C 0.50 0.55 110.00 1.63
D 0.50 0.51 102.00 1.71
Ca A 0.50 0.51 102.00 0.57
B 0.50 0.53 106.00 0.59
C 0.50 0.53 106.00 0.66
D 0.50 0.52 104.00 0.71
Mg A 0.50 0.53 106.00 0.44
B 0.50 0.52 104.00 0.47
C 0.50 0.51 102.00 0.52
D 0.50 0.53 106.00 0.44
Al A 2.00 2.10 105.00 0.86
B 2.00 2.15 107.50 0.91
C 2.00 2.16 108.00 0.78
D 2.00 2.18 109.00 0.84
Fe A 5.00 5.45 109.00 1.12
B 5.00 5.42 108.40 1.37
C 5.00 5.50 110.00 1.21
D 5.00 5.51 110.20 1.45
Si A 2.00 2.17 108.50 1.07
B 2.00 2.15 107.50 1.09
C 2.00 2.14 107.00 1.16
D 2.00 2.10 105.00 1.20
P A 0.50 0.54 108.00 1.29
B 0.50 0.55 110.00 1.48
C 0.50 0.58 116.00 1.35
D 0.50 0.56 112.00 1.30