表2 实验设计方案及结果
序号H2O2投加量/(mmol·L-1Fe2+浓度/(mmol·L-1pH反应时间/min降解率/%
10.870.255.06091.33
20.140.155.02060.22
31.600.155.06074.93
40.140.055.04034.13
50.870.155.04058.65
60.140.255.04059.81
71.600.153.04084.30
80.870.055.06040.71
90.140.157.04038.87
100.870.053.04050.02
110.140.153.04060.40
121.600.157.04040.30
130.140.155.06062.89
140.870.257.04057.69
151.600.155.02071.11
160.870.155.04059.65
170.870.155.04057.65
181.600.255.04082.87
190.870.057.04014.43
200.870.153.02082.52
210.870.255.02078.47
220.870.155.04058.65
230.870.253.04084.92
240.870.157.02045.82
250.870.153.06081.23
260.870.055.02039.10
271.600.055.04030.19
280.870.157.06055.23
290.870.155.04057.65