A solid water treatment corrosion inhibitor-slow dissolving ball has been developed according to the fact that sodium tetraborate has excellent corrosion inhibition performance, while the preparation of liquid agent cannot meet the use requirements due to its poor solubility. The influences of the dosage of the inhibitor and temperature on the corrosion inhibition rate were studied by rotary coupon test, and the solubility and corrosion inhibition performance of the product were tested. The results showed that when the water temperature was lower than 40℃, the dissolved amount of the slow dissolving ball had little change and was relatively stable. When the water temperatures were 35℃, 45℃ and 55℃, the corrosion rate of carbon steel was obviously lower than the national standard of 0.075 mm/a with 28.5 mg/L slow dissolving ball dosage.
Keywords:
本文引用格式
郭茹辉, 王深琳, 李海花, 何蕊, 高玉华, 刘振法.
Guo Ruhui.
目前,市售水处理缓蚀剂以液体为主,是由一种或几种具有缓蚀作用的物质复合到水溶液中构成的,产品的含水量一般为70%~80%。但由于各缓蚀物质的物理、化学性质并不相同,溶解性差距较大,导致许多缓蚀物质不能同时按照质量配比要求溶解到水溶液中,形成液体缓蚀剂;另外有些物质在水溶液中的稳定性差,易析出,缩短了产品存放时间,影响了产品的缓蚀性能。总之,有许多缓蚀作用优良的物质不能按照理想的量复合到水溶液中〔3〕。针对上述现象,本研究通过固体混合后压制成型,采用长效缓溶的形式对缓蚀性能优良、溶解性较差的缓蚀剂加以利用,制备出固体水处理缓蚀剂——缓溶球。实验结果表明,该产品能够充分发挥各缓蚀物质的协同作用,具有优良的缓蚀性能。
1 实验部分
1.1 实验水样水质
实验水样为沧州市亚诺化工有限公司的补充水,其水质:pH=7.8,钙硬度128.5 mg/L,镁硬度106.4 mg/L,总碱度83.5 mg/L,电导率469 μS/cm,氯离子52.8 mg/L。
1.2 试剂与仪器
试剂:葡萄糖酸钠,中信化学有限公司;四硼酸钠,辽宁硼达科技有限公司;HEDP钠盐,山东东方化工有限公司;EDTA,河北科隆多生物科技有限公司;硫酸锌,石家庄金旭化工科技有限公司;添加剂硬脂酸钠,河南铭之鑫化工产品有限公司;甘露醇,河北五百科技有限公司;苯并三氮唑,南京顺恒信化工有限公司。缓蚀剂TS-709(由六偏磷酸钠、磷酸三钠等固体组成),互丰化工有限公司;液体HB-931(由钼酸盐、无机缓蚀剂和调节剂组成),河北蓝清水处理科技有限公司;液体HF-301(由有机磷酸盐、无机磷酸盐、锌盐等复配而成),安宁欣凯丰环保科技有限公司。所用试剂均为工业品。
仪器:724型分光光度计,上海光学仪器厂;JA-4103型电子天平,上海天平仪器厂;SCRCC型旋转挂片腐蚀试验仪(10孔),北京海富达科技有限公司;A3型碳钢试片(50 mm×25 mm×2 mm),高邮市新邮仪器厂。
1.3 缓蚀剂——缓溶球的制备
四硼酸钠为白色易流动的晶体颗粒,其在水中的溶解度比较低,常温下溶解度<3.5 g。四硼酸钠主要用作金属材料的缓蚀剂,在冷却水系统为阳极型缓蚀剂〔4〕。水中的硼酸盐有利于溶解氧在金属表面的吸附,进而可促进金属材质钝化;硼酸盐吸附在金属表面氧化膜上,可使氧化膜更稳定、更牢固,从而起到缓蚀作用;金属表面吸附的硼酸盐还能阻滞金属电极的阳极反应过程。四硼酸钠低毒,对环境无污染,并有杀菌作用〔5〕。单独使用该药剂,用量较大,因此需要与其他缓蚀产品进行复配使用。经过多次旋转挂片腐蚀实验,确定配方主要成分为四硼酸钠、葡萄糖酸钠、HEDP钠盐及添加剂等。将四硼酸钠、葡萄糖酸钠、HEDP钠盐及添加剂按质量比15∶10∶3∶0.5进行配制,并充分搅拌使之混合均匀,然后通过THP-10花篮式压片机压制,得到固体水处理缓蚀剂——缓溶球。现场投加缓溶球装置是带缝隙的塑料筐,为了易于投加和保证溶解量,并参考缝隙大小,确定缓溶球的直径为4 cm。
1.4 缓溶球溶解性能的测定
在一定温度下,将产品悬于l 000 mL水中,在静态或搅动状态下恒温24 h。取出全部水,更换1 000 mL新水,重复上述实验至产品接近全部溶解。每天取出一定量被换下的水,采用比色法测定水中磷酸盐的含量,计算产品溶解量〔6〕。
式中:P——实验水中磷酸盐质量浓度,mg/L;
V——实验水体积,L;
M——HEDP钠盐中磷酸盐质量分数,%;
N——缓溶球中HEDP钠盐质量分数,%;
D——实验时间,d。
1.5 缓蚀性能评价方法
1.5.1 旋转挂片实验法
按照《水处理剂缓蚀性能的测定旋转挂片法》(GB/T 18175—2014)进行腐蚀实验。采用SCRCC型旋转挂片腐蚀试验仪(10孔),试片为A3碳钢挂片,所用实验水为沧州市亚诺化工有限公司的补充水,实验温度(45±1)℃,转速75 r/min,时间72 h。
1.5.2 电化学腐蚀实验
电化学阻抗测试在开路电势下进行,正弦扰动电位变化幅度为5 mV,交流信号变化范围为0.05~100 000 Hz,Tafel极化曲线测试范围为±300 mV,扫描速率为1 mV/s。
2 实验结果与讨论
2.1 旋转挂片法研究缓溶球的缓蚀性能
2.1.1 药剂用量对缓蚀率的影响
缓溶球用量对缓蚀率的影响如图 1所示。
图1
由图 1可知,随着药剂用量的增加,缓蚀率不断提高,当药剂投加量为28.5 mg/L时,缓蚀率为96.8%,腐蚀率为0.030 6 mm/a,此时的腐蚀率已完全达到国家标准要求。继续增加药剂用量,缓蚀率的变化趋于平稳。从经济方面考虑,缓溶球适宜的投加量为28.5 mg/L。
2.1.2 温度对缓蚀率的影响
一般工业循环冷却水的温度低于55 ℃,因此选取35、45、55 ℃代表循环水的常用温度进行挂片腐蚀实验,药剂投加量为28.5 mg/L。实验结果见表 1。
表1 不同温度下的缓蚀效果
温度/℃ | 失重/g | 腐蚀率/(mm·a-1) | 缓蚀率/% |
35 | 0.004 4 | 0.024 3 | 97.46 |
45 | 0.005 5 | 0.030 6 | 96.80 |
55 | 0.010 1 | 0.055 9 | 94.15 |
由表 3可以看出,随着温度的升高,腐蚀率升高,缓蚀率下降。当温度为35、45、55 ℃时,腐蚀率分别为0.024 3、0.030 6、0.055 9 mm/a,均低于国家标准的0.075 mm/a。实验结果表明,制备的缓蚀球在不同温度下对A3碳钢均有良好的缓蚀效果,能够保证换热设备和管道的正常运转。
2.2 缓溶球的溶解性能
2.2.1 缓溶球的溶解量
取样品120 g,在温度25 ℃条件下进行缓溶球溶解性的测定,结果见表 2。
由表 2可知,缓溶球每天的溶解量较小,在长达7 d的时间内,缓溶球每天的溶解量均维持在14~16 mg/g,比较稳定。
2.2.2 温度对缓溶球溶解性能的影响
取120 g缓溶球,分别在10、20、25、30、40、50、60 ℃下进行溶解性能测试, 结果见表 3。
由表 3可知,当温度<40 ℃时, 随着温度的升高,缓溶球的溶解量变化不大;当温度>40 ℃时,溶解速度增加,溶解量明显上升。在实际工业应用中,一般补水的温度在30 ℃以内,溶解量变化不大,可避免药剂的浪费,对产品的使用无影响。产品的溶解量可以控制在使用范围内。
2.3 电化学方法研究缓溶球的缓蚀作用
2.3.1 Tafel极化测试结果
图 2是空白溶液和加入28.5 mg/L药剂后的Tafel极化曲线。
图2
2.3.2 电化学阻抗测试结果
图 3是空白溶液和添加28.5 mg/L药剂后得到的阻抗图谱。
图3
从图 3可以看出,加入复合药剂后的阻抗图谱和空白样品的阻抗图谱显示基本相同的特征,在高频区有一半圆弧,表示电荷传递电阻。加入复合药剂后,半圆弧明显增大,即电阻增大,相应的电流减小,说明该药剂对于金属(A3碳钢)的腐蚀起到了很好的抑制作用,降低了腐蚀速率。
2.3.3 缓蚀机理
制备的缓溶球中,各缓蚀组分之间具有良好的协同效应。硼酸盐能够吸附在金属表面氧化膜上,使得氧化膜更稳定、更牢固,从而起到缓蚀作用;葡萄糖酸钠是一种吸附膜型缓蚀剂,可以与铁离子形成螯合物,在碳钢表面成膜,但成膜时间长;HEDP钠盐是一种有机磷酸类阻垢缓蚀剂,能与铁、铜、锌等多种金属离子形成稳定的络合物,能溶解金属表面的氧化物,在250 ℃下仍能起到良好的缓蚀作用。将这几种成分复配后则显示出极好的缓蚀效果。原因在于硼酸盐成膜较快,弥补了葡萄糖酸钠成膜慢的缺点;而分子较小的葡萄糖酸钠加入后形成吸附膜,弥补了硼酸盐和HEDP钠盐所形成的膜的不足,使形成的缓蚀膜更具完整,更加致密,从而提高了缓蚀效率。
2.4 缓溶球与常用缓蚀剂的缓蚀性能对比
缓溶球与常用缓蚀剂的缓蚀性能对比见表 4。
表4 缓溶球与常用缓蚀剂缓蚀性能的比较
药剂名称 | 加药量/(mg·L-1) | 腐蚀率/(mm·a-1) | 缓蚀率/% |
缓溶球 | 28.5 | 0.028 6 | 97.00 |
HF-301 | 50 | 0.075 5 | 92.01 |
TS-709 | 60 | 0.080 3 | 91.60 |
HB-931 | 50 | 0.098 9 | 89.65 |
空白 | 0 | 0.956 2 | — |
由表 4可以看出,缓溶球的缓蚀效果明显好于HF-301、TS-709、HB-931缓蚀剂。
3 结论
(1)以四硼酸钠、葡萄糖酸钠、HEDP钠盐及添加剂为主要成分制备出固体缓蚀剂——缓溶球,这4种成分的质量比为15∶10∶3∶0.5。旋转挂片腐蚀实验结果表明,当缓溶球投加量为28.5 mg/L时,碳钢的腐蚀率为0.030 6 mm/a,完全达到国家规定标准。
(2)Tafel极化测试结果表明,缓蚀剂的加入可以抑制阳极铁的氧化反应,而阴极极化曲线较原液变化较小,说明此种水处理剂以抑制阳极为主。
(3)缓溶球的溶解度随着温度的提高呈逐渐增大的趋势,当温度<40 ℃时, 随温度的升高,缓溶球的溶解度变化幅度不大;当温度>40 ℃时,溶解速度增加,溶解度明显上升。