表2 蒸发塔运行数据
|
Table 2 Evaporation tower operating data
|
|
蒸发水量/(m3·h-1) | A侧蒸发水量/(m3·h-1)B | 侧蒸发水量/(m3·h-1) | A侧抽取的烟气量/(Nm3·h-1) | A侧抽取的烟气量比例/% | B侧抽取的烟气量/(Nm3·h-1) | B侧抽取的烟气量比例/% | 锅炉负荷比值/% | 4.47 | 2.27 | 2.20 | 26 047 | 5.94 | 26 599 | 6.07 | 80 | 5.89 | 2.95 | 2.94 | 26 889 | 5.61 | 27 246 | 5.69 | 87 | 5.95 | 2.94 | 3.01 | 26 898 | 5.64 | 27 016 | 5.66 | 87 | 5.88 | 2.90 | 2.98 | 26 870 | 5.65 | 26 895 | 5.65 | 87 | 5.74 | 2.81 | 2.93 | 26 850 | 5.64 | 26 877 | 5.65 | 87 | 5.83 | 2.87 | 2.96 | 26 878 | 5.65 | 26 987 | 5.67 | 86 | 5.89 | 2.88 | 3.01 | 26 890 | 5.65 | 27 010 | 5.68 | 86 | 5.74 | 2.78 | 2.96 | 26 785 | 5.63 | 26 980 | 5.67 | 86 | 5.75 | 2.75 | 3.00 | 26 760 | 5.82 | 26 988 | 5.87 | 84 | 4.00 | 1.81 | 2.20 | 19 025 | 6.02 | 18 780 | 5.94 | 58 |
|
|
|