表1 加氧用补给水量与加氧补水率计算结果
Table 1 Calculation results of make-up water amount and water percentage of feed water oxygenated
V(GB)/(t?h-1 DO(BJ)*/(mg?L-1 ADO/(μg?L-1 V(OT)/(t?h-1) ω/%
1 800 8 10 2.25 0.125
1 800 8 20 4.50 0.250
1 800 8 30 6.75 0.375
1 800 8 40 9.00 0.500
1 800 8 50 11.25 0.625
1 800 8 64 14.40 0.800
1 800 8 80 18.00 1.000