| 反渗透膜污染原因分析及清洗技术在电厂的应用
 | 
		
		| 顿小宝,郑勃,郭云飞,杨敏,鲁浩 | 
			
			| Analysis of reverse osmosis membrane fouling and application of cleaning technology in power plants
 | 
		
		| Xiaobao DUN,Bo ZHENG,Yunfei GUO,Min YANG,Hao LU | 
	
		|  | 
	
		| 表2 反渗透清洗记录 
 | 
	
		| Table 2 Reverse osmosis cleaning record 
 | 
	
		|  | 
	
		| | 项目 | 时间 | 流量/(m3·h-1) | 压力/MPa | 温度/℃ | pH | 
|---|
 | #1反渗透 | 12:55 | 110.0 | 0.25 | 31 | 中性 |  | 14:05 | 110.0 | 0.35 | 33 | 中性 |  | 14:35 | 110.0 | 0.30 | 37 | 12.0 |  | 17:05 | 105.0 | 0.27 | 37.3 | 11.7 |  | 19:00 | 111.0 | 0.27 | 36.3 | 11.8 |  | 20:00 | 111.0 | 0.27 | 37.4 | 11.7 |  | #2反渗透 | 18:00 | 88.0 | 0.30 | 25.1 | 中性 |  | 19:00 | 92.5 | 0.30 | 30.6 | 中性 |  | 20:00 | 92.8 | 0.30 | 35.0 | 12.0 |  | 21:00 | 92.0 | 0.33 | 40.0 | 12.0 |  | 22:00 | 109.0 | 0.28 | 36.6 | 11.7 |  | 23:00 | 106.6 | 0.25 | 38.4 | 11.6 |  | 24:00 | 104.8 | 0.24 | 37.7 | 11.5 | 
 | 
	
		|  | 
	
		|  |