尿素漏入对机组水汽品质的影响及关键诊断技术
熊远南

Effects of urea leakage into boiler thermodynamic system on steam-water quality and key techniques on diagnose its existence in coal power units
Yuannan XIONG
表1 1号机组水样DGCC测试值与在线表计显示值 (μS/cm)
Table 1 Test value of water-steam degassed cation conductivity and displayed value of water-steam conductivity on line chemical instruments in power unit of one
送样时间水样名称CCDGCC比电导率(SC)

2021年

1月8日

凝结水泵0.1490.1396.019
除氧器进口0.0930.0825.691
省煤器进口0.9670.0915.897
主蒸汽1.0120.0966.021
再热蒸汽0.9840.1036.135