超声辅助热碱洗-电化学法联合处理含油浮渣
|
|
吴潮汉,李阳,边婷婷
|
Combined ultrasonic-assisted thermokalite washing with electrochemical method for the treatment of oily scum
|
|
Chaohan WU,Yang LI,Tingting BIAN
|
|
表2 正交实验结果
|
Table 2 Orthogonal experimental results
|
|
| 实验号 | 因素 | 干基含油率/% |
|---|
| 热洗pH | 热洗温度/℃ | 超声功率/W |
|---|
| 1 | 10 | 65 | 560 | 18.46 | | 2 | 10 | 70 | 630 | 18.43 | | 3 | 10 | 75 | 700 | 17.38 | | 4 | 11 | 65 | 630 | 19.19 | | 5 | 11 | 70 | 700 | 17.99 | | 6 | 11 | 75 | 560 | 18.30 | | 7 | 12 | 65 | 700 | 18.39 | | 8 | 12 | 70 | 560 | 18.48 | | 9 | 12 | 75 | 630 | 18.66 | | K1 | 54.27 | 56.04 | 55.24 | — | | K2 | 55.48 | 54.90 | 56.28 | — | | K3 | 55.53 | 54.34 | 53.76 | — | | k1 | 18.09 | 18.68 | 18.41 | — | | k2 | 18.49 | 18.30 | 18.76 | — | | k3 | 18.51 | 18.18 | 17.92 | — | | 极差R | 1.26 | 1.70 | 2.52 | — | | 偏差平方和 | 0.51 | 0.75 | 1.60 | — | | 优选方案 | 10 | 75 | 700 | 17.38 |
|
|
|