两级A2/O+磁混凝工艺处理农村生活污水工程实例
丁付革, 沈志伟, 张骏, 甘雁飞

An engineering case of rural domestic sewage treatment by two-stage A2/O+magnetic coagulation process
Fuge DING, Zhiwei SHEN, Jun ZHANG, Yanfei GAN
表1 设计进、出水水质
Table 1 Design influent and effluent quality
项目pH

COD/

(mg·L-1

氨氮/

(mg·L-1

TN/

(mg·L-1

TP/

(mg·L-1

SS/

(mg·L-1

设计进水6~9130~42025~5030~603.0~7.070~200
设计出水6~9505(8)150.510