预臭氧+MBR+后臭氧工艺在焦化园区污水厂改造中的应用
|
李志雷, 刘宝富, 陈秀娟, 张德祥
|
Application of combined process pre ozone plus MBR and post ozone in sewage plant technical transformation project of coking park
|
Zhilei LI, Baofu LIU, Xiujuan CHEN, Dexiang ZHANG
|
|
表4 臭氧氧化中试试验
|
Table 4 Pilot test record of ozonation
|
|
中试日期 | O3投加量/(mg·L-1) | 停留时间/h | 生化出水COD/(mg·L-1) | 臭氧出水COD/(mg·L-1) | COD去除率/% |
---|
2016-10-20 | 60 | 1.5 | 83 | 63.10 | 23.98 | 2016-10-20 | 60 | 2 | 83 | 61.55 | 25.84 | 2016-10-21 | 70 | 1.5 | 89 | 65.67 | 26.22 | 2016-10-21 | 70 | 2 | 89 | 64.00 | 28.09 | 2016-10-22 | 80 | 1.5 | 85 | 58.33 | 31.37 | 2016-10-22 | 80 | 2 | 85 | 56.43 | 33.61 | 2016-10-23 | 90 | 1.5 | 82 | 52.00 | 36.59 | 2016-10-23 | 90 | 2 | 82 | 49.10 | 40.12 | 2016-10-24 | 100 | 1.5 | 85 | 51.67 | 39.22 | 2016-10-24 | 100 | 2 | 85 | 49.29 | 42.02 | 2016-10-25 | 110 | 1.5 | 78 | 41.33 | 47.01 | 2016-10-25 | 110 | 2 | 78 | 38.71 | 50.37 | 2016-10-26 | 120 | 1.5 | 81 | 41.00 | 49.38 | 2016-10-26 | 120 | 2 | 81 | 38.14 | 52.91 | 2016-10-27 | 120 | 2.5 | 81 | 33.00 | 59.26 | 2016-10-28 | 120 | 2.5 | 80 | 32.10 | 59.88 | 2016-10-29 | 120 | 2.5 | 76 | 30.20 | 60.26 | 2016-10-30 | 120 | 2.5 | 87 | 39.31 | 54.82 | 2016-10-31 | 120 | 2.5 | 84 | 36.00 | 57.14 | 2016-11-1 | 120 | 2.5 | 79 | 31.54 | 60.08 |
|
|
|