工业水处理 ›› 2002, Vol. 22 ›› Issue (3): 35-37. doi: 10.11894/1005-829x.2002.22(3).35

• 试验研究 • 上一篇    下一篇

弱酸床处理循环冷却水系统防垢试验研究

于萍1, 罗运柏1, 许光辉2   

  1. 1. 武汉大学化学与环境工程系;
    2. 河南省驻马店地区古城发电厂 湖北武汉 430072
  • 收稿日期:2001-10-20 出版日期:2002-03-20 发布日期:2010-10-01
  • 作者简介:于萍(1963),1983年毕业于湖南大学化工系,博士,副教授

Prevention the cooling water system from scaling by using weak acid ion exchanger

YU Ping1, LUO Yunbai1, XU Guanghui2   

  1. 1. Department of Chemical and Environmental Engineering, Wuhan University, Wuhan 430072, China;
    2. Henan Gucheng Power Plant, Queshan 463200, China
  • Received:2001-10-20 Online:2002-03-20 Published:2010-10-01

摘要:

从调节循环冷却水的水化学工况入手,防止以弱酸床处理水作为循环冷却水补充水系统的结垢与腐蚀。实验室及现场运行试验结果表明,该方法行之有效。

关键词: 弱酸离子交换处理, 循环冷却水, 防垢

Abstract:

The chemical condition of cooling water in operation has been adjusted in weak acid ion exchange treatment fed to prevent the cooling water system from scaling.Experimental results in laboratory and power plant are very satisfactory.

Key words: weak acid ion exchange treatment, circulation cooling water, scale prevention