试验与研究

好氧生物流化床处理抗生素废水的试验研究

展开
  • 1.哈尔滨工业大学市政环境工程学院, 黑龙江 哈尔滨 150090;
    2.浦项工科大学化工系, 韩国 浦项
郗丽娟(1960- ),1982 年毕业于东北电力学院,高级工程师,主要从事电厂化学方面的研究,E-mail:xlj1960@yahoo.com.cn。

收稿日期: 2005-06-20

  网络出版日期: 2010-10-01

基金资助

国家重点基础研究发展计划973项目(2004CB418505)

Study on the treatment of antibiotic wastewater by aerobic fluidized-bed bioreactor

Expand
  • 1.School of Municipal &Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China;
    2. Department of Chemical Engineering, Pohang University of Science and Technology, Korea

Received date: 2005-06-20

  Online published: 2010-10-01

摘要

采用以新型高分子材料为生物载体的生物流化床工艺处理高浓度的抗生素废水。试验结果表明,该载体挂膜容易,启动快,一个月后载体附着的生物量可达4136mg/L,在载体表观体积为反应器总体积的50%、进水COD容积负荷低于2.5kg/(m3>·d)的情况下,COD去除率可达85%以上。该生物流化床对BOD5的去除率平均高达89.21%,与COD的去除率具有同步性。并研究了反应器中悬浮污泥浓度SS和总生物量MLSS在整个实验期间的动态变化,表明稳定运行时SS和总MLSS基本上稳定不变,当系统受到高负荷冲击时,SS降低,总MLSS升高,而且生物活性也大幅度提高,生物膜处在适应期,反应器抗冲击负荷能力增强。

本文引用格式

杜大恒, 陈胜, 孙德智, Jong Shik Chung . 好氧生物流化床处理抗生素废水的试验研究[J]. 工业水处理, 2005 , 25(12) : 29 -33 . DOI: 10.11894/1005-829x.2005.25(12).29

Abstract

A novel kind of polymer bio-carrier is applied to treat highly concentrated antibiotic wastewater by flui-dized-bed bioreactor.The experimental results show that this kind of bio-carriers has good property for microorganism habitat on it and quick starting up.The biomass attached on the carries is up to 4 136mg/L in one month; the COD removal efficiency of above 85% could be achieved when the bio-carriers apparent volume is 50% of the reactor volume and the influent COD volume loading is under 2.5 kg/(m3d).The average BOD5 removal efficiency is up to 89.21% at stable operation stage,which is simultaneous with the COD removal rate.The dynamic change of suspended sludge SS and total biomass MLSS during the whole operation period show that SS and MLSS are basically constant at stable stage.SS would decrease while MLSS increase when the reactor system suffers from high loading impact.What′s more,the microorganism activity is greatly enhanced,biofilm growth entered adaption step,which indicates that the ability of fluidized-bed bioreactor of resistance to high loading impact is strengthened.

参考文献

[1] 雷武,等.冷却水系统中阻垢剂性能的评定方法[J].化工进展,2002,21(4):225-227
[2] 张洪生.植酸在金属表面防护处理中的应用[J].材料保护,2000,33(3):18
[3] HG/T 2159-1991,水处理剂缓蚀性能的测定 旋转挂片法[S]
[4] HG/T 2024-1991,水处理药剂阻垢性能测定方法 鼓泡法[S]