试验研究

三维电极电化学方法处理印染废水实验研究

展开
  • 1. 华中科技大学环境科学与工程学院, 湖北 武汉 430074;
    2. 江汉石油学院化学工程系, 湖北 荆州 434023;
    3. 北京大学化学与分子工程学院, 北京 100871;
    4. 华南理工大学造纸与环境工程学院, 广东 广州 510641
陈武(1967- ),副教授,现为华中科技大学环境科学与工程院在读博士生,主要从事油气田环境保护的教学和科研工作.电话:0716-8431855,E-mail:ccww91@sohu.com

收稿日期: 2003-12-19

  网络出版日期: 2010-10-01

Study on the treatment of dyeing wastewater by using three dimensional electrode electrochemical method

Expand
  • 1. College of Environmental Science & Engineering, Huazhong University of Science & Technology, Wuhan 430074, China;
    2. Department of Chemical Engineering, Jianghan Petroleum University, Jingzhou 434023, China;
    3. College of Chemistry & Molecular Engineering, Beijing University, Beijing 100871, China;
    4. College of Paper & Environmental Engineering, South China University of Technology, Guangzhou 510641, China

Received date: 2003-12-19

  Online published: 2010-10-01

摘要

作者利用三维电极电化学方法进行了去除印染废水COD和色度的实验研究,取得了令人满意的脱色率和COD去除率,经三维电极处理10min后,COD去除率达89.03%,色度去除率达99.43%,印染废水经处理后能达到国家污水综合排放标准(GB8978—1996)Ⅰ级要求。为印染废水的处理提供了一种新的有效方法。

本文引用格式

陈武, 杨昌柱, 梅平, 董玲玲, 袁谷 . 三维电极电化学方法处理印染废水实验研究[J]. 工业水处理, 2004 , 24(8) : 43 -45 . DOI: 10.11894/1005-829x.2004.24(8).43

Abstract

The removal of COD and chromaticity of dyeing wastewater by using three dimensional electrode (TDE) have been studied. The result is satisfactory with 89.03% of removal rate of COD and 99.43% of decolouring rate after being electrolyzed for 10 minutes. The dyeing wastewater can meet the requirement of the First Grade Discharge Standard of China(GB 8978-1996). The study provides a new method for the treatment of dyeing wastewater.

参考文献

[1] 陈武,李凡修,梅平.废水处理的电化学方法研究进展[J].湖北化工,2001,18(1):10-12
[2] Lee J K. Studies of bipolarity in fiuidized bed electrode[J]. Journal of Applied Electrochemistry, 1989, (19):877 - 881
[3] Kerysa G, et al. Cylindrical three-dimensional electrodes under limiting current conditions [ J]. J. Appl., Electrochem., 1993, (23):707-714
[4] 袴田晴夫,等.被处理水の电気化学的处理方法[P].JP 4016286,1992
[5] 伊藤健治.污液中の污染物质分离方法び处理装置[P].JP 60014987,1985
[6] Augusto Porta, et al. Process for the electrochemical decontamination of water polluted by pathogenic germs with peroxide formed in situ[P]. US 4619745,1986
[7] 陈武,李凡修,梅平.三维电极方法处理石油工业废水COD实验研究[J].环境科学与技术,2001,24(增刊):6-9
[8] 陈武,李凡修,梅平.三维电极方法降解模拟废水COD机理研究[J].环境科学与技术,2002,25(1):11-12
[9] 陈武,艾俊哲,李凡修,等.利用扫描电镜研究三维电极主电极表面腐蚀状况[J].江汉石油学院学报,2002,24(3):108-110
[10] 陈武,艾俊哲,李凡修,等.电化学反应器--三维电极中粒子电极应用研究[J].荆州师范学院学报,2002,25(5):76-78
[11] 国家环保局<水和废水监测分析方法>编委会.水和废水监测分析方法[M].第3版.北京:国环境科学出版,1989.354-356

文章导航

/