Application of HAR-biological contact oxidation process to the treatment of domestic sewage

Expand
  • The Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China

Received date: 2005-02-20

  Online published: 2010-10-01

Abstract

Hybrid anaerobic reactor(HAR), followed by biological contact oxidation(BC) technique, is used for treating domestic sewage. When HAR is under operation for 31 d and the water temperature is 15℃, the COD removal rate is up to over 60%. When outlet water is treated by biological contact oxidation, HRT is 3.2 h, the COD of outlet water is less than 40 mg/L averagely, SS less than 12 mg/L, BOD5 and NH3 less than 15 mg/L. The results show that HAR and BC techniques can be used for treating domestic sewage in areas where the climate is suitable.

Cite this article

Jiang Zhuwu, Luo Lin, Zhao Jianfu . Application of HAR-biological contact oxidation process to the treatment of domestic sewage[J]. Industrial Water Treatment, 2005 , 25(7) : 23 -25 . DOI: 10.11894/1005-829x.2005.25(7).23

References

[1] Alaerts G J, et al.Feasibility of anaerobic sewage treatment in sanitation strategies in developing countries[J].Wat.&Sci.Tech., 1993, 27:179-186
[2] Kalker T J J, et al.Transfer and acceptance of UASB technology for domestic wastewater:two case studies[J].Wat.&Sci.Tech., 1999, 39(5):219-255
[3] Lettinga G, et al.Challenge of psychrophilic anaerobic wastewater treatment[J].Trends in Biotech., 2001, 19(9):363-370
[4] 贺延龄.废水的厌氧生物处理[M].北京:中国轻工业出版社, 1998.1-3