Study on phenol一cyanogen wastewater treatment by sequencing batch reactor process

Expand
  • Hunan University of Science and Technology, Xiangtan 411201,China

Received date: 2004-11-29

  Online published: 2010-10-01

Abstract

Using sequencing batch reactor(SBR)to treat phenol-cyanogen wastewater from coking plants has been conducted. The effect of aeration time and sludge loading are discussed. Experimental results show that: when mixed liquid suspended solid is 4 g/L,sludge loading is 0.15 kg/(kg·d)and aeration time is 4 h,the removal efficiency of COD reaches 86.6%,that of phenol reaches 99.7%,cyanogen reaches 95.9%. It has better disposal result of NH3 - N if changing this running process of SBR.

Cite this article

Qiu Xiyang,Shi Hongwen,Ma Songjiang . Study on phenol一cyanogen wastewater treatment by sequencing batch reactor process[J]. Industrial Water Treatment, 2005 , 25(5) : 50 -52 . DOI: 10.11894/1005-829x.2005.25(5).50

References

[1] 顾国维.水污染治理技术研究[M].上海:同济大学出版社, 1997. 147-173
[2] 尹承龙,孟祥荣,曹晓梅.焦化废水处理技术的进展[J].燃料与化工,2002, 31(6):303-306
[3」陈国喜,詹伯君.SBR生化系统的应用及其发展[J].环境科学进展,2001,6(22):35-39
[4」胡家骏,周群英.环境工程微生物学[M].北京:高等教育出版社,2000. 32-42
[5] 陈坚.环境生物技术[M].北京:中国轻工业出版社,1999. 116 - 119
[6] 国家环保局.水和废水监测分析方法[M].中国环境科学出版社, 1997. 102-464
[7] 侯瑞琴,等.间歇式活性污泥法污水处理技术及工程实例[M]. 北京:化学工业出版社,2002. 64 - 65