Abstract

This is a pilot-test study.It treats the secondary water of wastewater treatment plant in Shanghai Petrochemical Co.by using combinative technics of coagulation and sedimentation, sandflow filtration, micro-electrolysis bactericide, then carrying out the reuse treatment.The treated water can be used as circulating cooling water.The test shows wastewater reuse device can easily work continuously and provides good efficiency.CODCr can be reduced from an average of 70.18 mg/L to 39.88 mg/L, turbidity can be reduced from an average of 30.83 NTU to 1.58 NTU,SS can be reduced from an average of 27.67 mg/L to 1.61mg/L and the total number of bacteria can be reduced to less than that in the standard of reuse water(100 mL-1).Furthermore, the device has good impact resistance.

Cite this article

Zhao Chenlong, Liu Weiguo . Researches on the reuse of secondary water in Petrochemical Company[J]. Industrial Water Treatment, 2004 , 24(7) : 30 -32,53 . DOI: 10.11894/1005-829x.2004.24(7).30

References

[1]刘卫国,等.一种用于混凝沉淀法处理污水的斜管沉淀池[P].CN02216236.4,2002
[2]刘卫国,等.一种用于处理污水的斜管沉淀池[P].CN02283644.6,2002
[3]李本高.循环冷却水处理技术面临新的形势和挑战[J].石油化工环境保护,2001,24(1):60-63
[4]张德胜,高廷耀.微电解杀菌器的研制和应用[J].中国给水和排水,1988,14(5):4-5
[5]建筑工程常用数据系列手册编写组.给水排水常用数据手册[M].北京:中国建筑工业出版社,1997.63
[6]CFCS-1993,污水回用设计规范[S]
[7]GB 50050-1995,工业循环冷却水处理设计规范[S]