Analysis of the utmost recovery rate of insoluble salts in the reverse osmosis system
Online published: 2010-10-01
Based on the analysis of feed water insoluble salts saturation in the reverse osmosis system the factors including temperature, pH value, recovery rate, scale inhibitor and the concentration polarization are considered, and the formula of system utmost recovery rate is established too. This will provide a simple and clear method the calculate the reverse osmosis system utmost recovery rate index.
Bi Fei, Jing Dawei . Analysis of the utmost recovery rate of insoluble salts in the reverse osmosis system[J]. Industrial Water Treatment, 2004 , 24(6) : 14 -16 . DOI: 10.11894/1005-829x.2004.24(6).14
[l] 靖大为, 徐腊梅. 小型反渗透膜系统优化结构设计[J]. 工业水处理, 2003, 23(3):65-68
[2] 时均, 袁权, 高从阶. 膜技术手册[M]. 北京: 化学工业出版社, 2001. 278-288
[3] 冯逸仙, 杨世纯. 反渗透水处理工程[M]. 北京: 中国电力出版社, 2000. 74-81
/
〈 |
|
〉 |