Abstract

A process named ion exchange micro-basification is put forward in the treatment of turbo-generator inner cooling water. The process translates the minim soluble Cu(HCO3)2 into NaOH, regulating solution alkalescent and restraining copper corrosion effectively. Field bypass simulated experimental results show that the small exchange column, which is composed of cation exchanger resin of Na-type and anion exchanger resin of OH-type by equal proportion of exchange capacity, is able to change the light acidic inner cooling water with an average Cu2+ content of 371.0 μg/L into light basic water nearly without Cu2+. The pH of the effluent from the ion exchange mixed bed is in the range of 7.60 to 8.95. The copper tested before and after the small exchange column shows that the cooling water treated by resin has an obvious effect on restraining copper corrosion.

Cite this article

Ye Chunsong, Zhang Jin, Qian Qin, Fan Shengping . Study on the turbo-generator inner cooling water treated by ion exchange micro-basification[J]. Industrial Water Treatment, 2004 , 24(6) : 17 -19 . DOI: 10.11894/1005-829x.2004.24(6).17

References

[1] 林婵希, 梁世荣, 农翠坚. BTA+EA防腐处理在发电机内冷水系统中的应用[J]. 广西电力技术, 1995, (1):49-52
[2] 龚洵洁. 热力设备的腐蚀与防护[M]. 北京: 中国电力出版社, 1998. 197-198
[3] 张澄信, 陈志和. 离子交换水处理试验研究原理[M]. 武汉: 华中理工大学出版社, 1997. 31-38