Received date: 2003-03-30
Online published: 2010-10-01
China University of Tethnology,Guangzhou510640,China) Based on experimentsin lab,pilot-plant study of the bleaching and dyeing wastewater treatment hasbeen carried on.The result showsthat after the technology which includesthe pivotal facility of highly efficient in-tegral wastewater treating equipment isused,in combination with the two-stage sand filtration,to treat thiskind of wastewater,the COD Cr of the treated wastewater isonly92~138mg/L,itspH value is6.3,and the suspended solid is20mg/L.All of the treated water can be reused.It doesn't have any ill effect,but makesgood economic profits.
Zhou Shenqiao, Ma Yongwen, Wan Jinquan . Pilot study of bleaching and dyeing wastewater treatment[J]. Industrial Water Treatment, 2004 , 24(1) : 47 -49 . DOI: 10.11894/1005-829x.2004.24(1).47
/
〈 |
|
〉 |