Determination of the scale inhibitor concentration of backwater system from the store field of coal ash

Expand
  • Wuhan University of Hydraulic and Electric Engineering,Wuhan 430027,China

Received date: 2000-09-15

  Online published: 2010-10-01

Abstract

The theoretical calculation formula of the scale velocity of backwater system f rom the store field of coal ash has been deduced in this paper.It show s that mass rat io of coal ash water, water temperature, scale inhibitor concent rat ion, backwater flow and so on are the main factors which affect the scale velocity.The determinat ion of the parameters GCaand f by simulated backwater is int roduced.It combines the power plant w ith pract ice, and explains how to use the formula to determine the scale inhibitor concentrat ion.

Cite this article

ZHOU Bai-qing . Determination of the scale inhibitor concentration of backwater system from the store field of coal ash[J]. Industrial Water Treatment, 2001 , 21(4) : 4 -7 . DOI: 10.11894/1005-829x.2001.21(4).4

References

[1] 朱琴英,等.火电厂灰水回收系统防垢技术的研究[J].电力环境保护,1994,10(2):1~12.
[2] 陈建明,等.灰水闭路循环水系统结垢的防止[J].华东电力,1997,(10):19~21.

Outlines

/