Study of the treatment of gentamicin wastewater by adsorption-coagulation-advanced chemical oxidation

Expand
  • 1. Chemistry and Chemical Engineering College of Henan University,Kaifeng 475001,China;
    2. South China University of Technology,Guangzhou 510641,China

Received date: 2000-11-25

  Online published: 2010-10-01

Abstract

The process of adsorption-coagulation-advanced chemical oxidation is used to treat gentamicin wastew ater and the best conditions of coagulation and oxidation are selected. Under the condition of pH 8, the effect of the coagulating treatment of the waste water is better when PAC and CPAM are used as coagulants and their feeding amount are 400 mg/ L and 10 mg/ L, respect ively. Then, when pH is equal to 3, the wastewater treated above is oxidized by H2O2/ Fe2+/ UV. When the exposure time of UV-light is 6 h, the satisfactory treatment effect is obtained. Experimental results show that, for gentamicin wastewater, the removal ratio of CODCr is 99. 1% and decolourisation rate is 100% by using the process. The gentamicin wastewater treated can reach the effluent standard of medical waste water.

Cite this article

LI De liang, LI Ming yu, WU Shu bin, TIAN Yi lin, LI Dan, LI Peng . Study of the treatment of gentamicin wastewater by adsorption-coagulation-advanced chemical oxidation[J]. Industrial Water Treatment, 2001 , 21(6) : 16 -19 . DOI: 10.11894/1005-829x.2001.21(6).16

References

[1] 姜家展, 季斌, 高难度抗生素有机废水处理[J]. 中国给水排水,1999, 15( 3) : 517~ 518
[2] 杨军, 陆正禹, 胡纪萍, 等. 抗生素工业废水处理技术的现状与展望[J]. 环境科学, 1997, 18( 3) : 83~ 85
[3] 周平, 钱易, 李炳伟, 等 厌氧?? 好氧混凝工艺处理抗生素废水[J] 中国给水排水, 1996, 12( 2) : 4~ 6
[4] Legrni O, Oliveros E, Braun A M. Photochemical processes for watert reatment [J]. Chem. Rev. , 1993, 93: 691~ 69
[5] 刘勇弟, 徐寿昌, 紫外-ent on 试剂的作用机理及在废水处理中的应用[J]. 环境化学, 1994, 13( 4) : 302~ 306

Outlines

/