The determination of Al2O3 and 5 elements in poly aluminium chloride by inductively coupled plasma mass spectrometer method

Expand
  • Shenzhen Water Supply Group Co. , Ltd, Shenzhen 518031, China

Received date: 1999-12-20

  Online published: 2010-10-01

Abstract

A method for the determination of Al2O3 and 5 elements Al 、As 、Mn 、Hg 、Pb 、Cd in poly aluminium chloride by inductively coupled plasma mass spectrometer (ICP —MS)has been established.They found Al2O3 and these 5 elements in polyaluminium chloride could be simultaneously determined by ICP —MS.The contents of Al2O3 and As 、Mn 、Hg 、Pb 、Cd in test sample (100 times dilution)are 0.30 %,1.87μg/ L,95.4μg/L,46.0 ng/L,23.3 μg/ L,574 ng/L respectively,and the accuracies of this test are 93.0 %,109 %,94.4 %,88.3 %,98.0 %,88.6 % respectively.

Cite this article

NONG Jinqi, LU Yixin, ZHURong . The determination of Al2O3 and 5 elements in poly aluminium chloride by inductively coupled plasma mass spectrometer method[J]. Industrial Water Treatment, 2000 , 20(2) : 35 -37 . DOI: 10.11894/1005-829x.2000.20(2).35

References

[1] 国家技术监督局.水处理剂—聚合氯化铝[S].GB15892 —1995.
[2] 魏复盛等.水和废水监测分析方法指南[M].北京:中国环境科学出版社,1997.
[3] Andrew D Eaton et al.S tandard Methods f or the Examinat ion ofWater and Wast ew at er[M].19th Edit ion.USA :1995.