Design and running analysis of the wastewater treatment from Huarun Beer Co., Ltd.
Received date: 2001-02-03
Online published: 2010-10-01
Based on the possibility of lab -scale experimental study, internal cycle hydrolysis acidification -aerobic process has been applied to the technology of the brewery wastewater treatment.The COD, BOD and SS in effluent at the final outlet are 74.7 mg/L, 12.9 mg/L and 14.28 mg/ L respectively meeting the National Discharge (GB8978 -1996).The analysis of the running efficiency shows that this process has many advantages, such as small land occupied, simple in equipment, good discharged water quality, easy management, less surplus sludge and no swelling of activated sludge,etc.
HAN Hongjun . Design and running analysis of the wastewater treatment from Huarun Beer Co., Ltd.[J]. Industrial Water Treatment, 2001 , 21(10) : 31 -33 . DOI: 10.11894/1005-829x.2001.21(10).31
[1] 韩洪军.水解酸化处理啤酒废水的试验研究[J].哈尔滨建筑大学学报,1999,(6):41~44.
[2] 陶有胜.水解酸化生物接触氧化工艺处理啤酒废水工程实例[J].环境工程,1998,16(4):20~22.
[3] Barnes D, et al.Surveys in industrial wastewater treatment[J].Food and Allied Industries,1984,1:101~102.
/
〈 |
|
〉 |