Technical improvement of the generator stator cooling water treatment in Songyu Power Plant, Xiamen
Received date: 2001-05-16
Online published: 2010-10-01
The reason for the impurity in the stator cooling water of 300 MW unit is analyzed.The technical countermeasure of water quality improvement is put forward.The result and experience of the technical improvement are summarized.This experience can be used as reference for thewater quality control of the stator cooling water in generators of the same kind and for chemical monitoring work.
CHEN Jinsheng . Technical improvement of the generator stator cooling water treatment in Songyu Power Plant, Xiamen[J]. Industrial Water Treatment, 2001 , 21(11) : 33 -35 . DOI: 10.11894/1005-829x.2001.21(1).33
[1] 王杏卿.热力设备的腐蚀与防护[M] .北京:水利电力出版社,1988.
/
〈 |
|
〉 |