Treating highly concentrated white wastewater in synthetic perfume production
Received date: 2001-10-10
Online published: 2010-10-01
Treat highly concentrated organic wastewater by using catalyst oxidation method,and screens out firstrank catalyst oxidation method.By this method,95%CODCr has been removed,achieving the Second National Discharging Standard,and its industry cost is low.It can be easily magnified in industry.It has better exploitation foreground.
Key words: cataly stoxidation; wastewatertreatment; organic wastewater; catalyst
SHI Fang, YANG Yuwang, LI Kairong . Treating highly concentrated white wastewater in synthetic perfume production[J]. Industrial Water Treatment, 2002 , 22(4) : 24 -26 . DOI: 10.11894/1005-829x.2002.22(4).24