The wastewater in pesticide plants on the supported bimetallic catalyst is treated and the operation condi tions of CWO including temperature,pressure,space velocity and the ratio of ai r/water are investig ated.It is found that the reduction of COD is 91.3 % at 245 ℃,4.2 MPa,SV 2.0 h -1 andV (air)∶V(water)=300.After CWO treatment,the ratio of the BOD5/CODCr of the wastewater is higher than 0.5 which ex hibits good biodegradability.
YANG Min, WANG Xiangao, DU Hongzhang, SUN Chenglin . Investigation on catalytic wet air oxidation of wastewater[J]. Industrial Water Treatment, 2002 , 22(4) : 35 -36 . DOI: 10.11894/1005-829x.2002.22(4).35