Chemical cleaning of 210 MW unit condenser for Shuangyashan Power Plant
Received date: 2002-04-08
Online published: 2010-10-01
The process of scale removal by acid cleaning for 210 MW unit condenser, and the chemical cleaning procedures, the check and evaluation of chemical cleaning effect are emphat ically int roduced. At last, the rates of scale and corrosion inhibitions are discussed thoroughly.
Key words: condenser; chemical cleaning; hydrochloric acid; erosion speed