Experimental studies on the treatment of leachate by interior electrolytic, anaerobic and aerobic processes

Expand
  • Wuzhou Engineering Design and Research Institute, Beijing 100053, China

Received date: 2002-06-02

  Online published: 2010-10-01

Abstract

The efficiencies and influential factors of the treatment of leachate with high concentration and ammonia -nitrogen are studied by interior electrolytic and aerobic processes.Test results show that when interior-electrolytic, anaerobic and aerobic processes are used in the treatment of leachate with high concentration and ammonia -nitrogen(CODCr 10 000 ~ 90 000 mg L and ammonia -nitrogen >600 mg L), the COD removal rate is up to 99 %, and the ammonia -nitrogen removal rate is up to 90 %.

Cite this article

ZUO Shenglong, ZHU Yanzhi, LIU Yaqi, MA Qian, CHI Zhengping . Experimental studies on the treatment of leachate by interior electrolytic, anaerobic and aerobic processes[J]. Industrial Water Treatment, 2002 , 22(10) : 35 -37 . DOI: 10.11894/1005-829x.2002.22(10).35

References

[1] 周律,等.厌氧生物反应器的启动及其影响因素[J].工业水处理,1996,16(5):1-3.

Outlines

/