Application of A/O+A/O biological contacted oxidation process to the wastewater treatment in industrial districts
Received date: 2002-04-06
Online published: 2010-10-01
An industrial wastewater treatment center in Rugao is taken as an example.The engineering design of A/O+A/O couple strengthening biological contacted oxidation process for the wastewater treatment in industrial districts is introduced. The scale of this treatment design is 20 000 m3/d, and the inlet water COD is 500 mg/L. After the treatment,the outlet water can reach the first grade of discharge standard of China. Besides, an ecological system has been set up in the A/O couple strengthening pond, providing a good approach to the comprehensive control and utilization of industrial district wastewater.
Zhang Li, Dou Yijian, An Lichao . Application of A/O+A/O biological contacted oxidation process to the wastewater treatment in industrial districts[J]. Industrial Water Treatment, 2003 , 23(1) : 62 -64 . DOI: 10.11894/1005-829x.2003.23(1).62
/
〈 |
|
〉 |