摘要:
在分析研究现有处理工艺的基础上,利用试验模型进行了水解酸化—两级曝气生物滤池(BAF)处理中药综合废水的中试研究,试验结果表明,当进水CODCr、SS、色度平均值分别为970 mg/L、145 mg/L、130倍时,出水CODCr、SS、色度平均值分别为80 mg/L、43 mg/L、35倍,达到了《污水综合排放标准》(GB 8978—1996)中的一级排放标准。
关键词:
中药综合废水,
水解酸化,
两级曝气生物滤池
Abstract:
Based on the analysis of the existing process, pilot test is made to investigate the treatment effect of traditional Chinese medicine complex wastewater by hydrolysis acidification and two-stage biological aerated filter(BAF). Results showthat the effluent CODCr,SS and color average values are 80 mg/L,43 mg/L and 35 times;in case when those in infloware 970 mg/L,145 mg/L and 130 times respectively. The effluent quality reaches Class Ⅰ Comprehensive Wastewater Discharge Standard (GB 8978—1996).
Key words:
Chinese medicine complex wastewater,
hydrolysis acidification,
two-stage biological aerated filter
中图分类号:
金必慧, 谢水波, 何少华, 陈泽昂, 黄爱武, 杨晶. 中药综合废水处理站技术改造中试研究[J]. 工业水处理, 2005, 25(10): 18-21.