工业水处理 ›› 2012, Vol. 32 ›› Issue (11): 43-46,47. doi: 10.11894/1005-829x.2012.32(11).43

• 试验研究 • 上一篇    下一篇

离子交换-还原沉淀耦合工艺处理含Cr(Ⅵ)废水试验研究

曾君丽1,2, 邵友元2, 易筱筠1   

  1. 1. 华南理工大学环境科学与工程学院, 广东 广州 510006;
    2. 东莞理工学院化学与环境工程学院, 广东 东莞 523808
  • 收稿日期:2012-08-13 出版日期:2012-11-20 发布日期:2012-11-29
  • 作者简介:曾君丽(1986- ), 硕士研究生电话:13412750373, E-mail: junli4685@yahoo.com.cn
  • 基金资助:

    973国家重点基础研究发展计划项目(2010CB227306);国家自然科学基金项目(51176036);东莞市高等院校科研机构和医疗卫生科技计划拟资助项目(201108102037)

Experimental research on the treatment of Cr(Ⅵ)-containing wastewater by coupling process of ion exchange-reduction precipitation

Zeng Junli1,2, Shao Youyuan2, Yi Xiaoyun1   

  1. 1. College of Environmental Science and Engineering, South China University of Technology, Guangzhou 510006, China;
    2. College of Chemistry and Environmental Engineering, Dongguan University of Science & Technology, Dongguan 523808, China
  • Received:2012-08-13 Online:2012-11-20 Published:2012-11-29

摘要:

为了高效、低成本地处理含Cr(Ⅵ)废水,提出采用离子交换-还原沉淀耦合工艺处理该废水。结果表明,将质量浓度为100 mg/L的含Cr(Ⅵ)废水以20 mL/min连续10.5 h流经离子交换柱,Cr(Ⅵ)的吸附率高达99.9%;用5%NaOH溶液洗脱饱和的离子交换树脂,洗脱液含Cr(Ⅵ)高达6 918.7 mg/L。FeSO4.7H2O还原处理浓缩后的高浓度含Cr(Ⅵ)废水的最佳反应条件为pH≥7,反应时间30 min,搅拌速度100 r/min,FeSO4.7H2O投加量为理论投加量的1.2倍,此条件下Cr(Ⅵ)去除率高达99.7%。

关键词: 含Cr(Ⅵ)废水, 离子交换树脂法, FeSO4.7H2O, 还原沉淀法

Abstract:

The coupling process of ion-exchange-reduction precipitation,has been carried out for treating the wastewater containing Cr(Ⅵ) with high efficiency and low cost. The results show that when the Cr(Ⅵ)-containing wastewater,whose mass concentration is 100 mg/L,is used for flowing through the ion exchange column continuously for 10.5 h,with 20 mL/min,the adsorbing rate of Cr (Ⅵ) is as high as 99.9%. 5% NaOH solution is used for eluting the saturated ion exchange resin. The Cr (Ⅵ ) contained in eluting liquid is as high as 6 918.7 mg/L. After the Cr(Ⅵ)-containing wastewater with high concentration is treated by FeSO4·7H2O reduction process. Under the following optimum reaction conditions:pH ≥7,reaction time 30 min,stirring speed 100 r/min,and dosage of FeSO4·7H2O 1.2 times of the theoretical amount,its Cr(Ⅵ) removing rate can be up to 99.7%.

Key words: wastewater containing Cr(Ⅵ), ion exchange resin method, ferrous sulfate, reduction precipitation process