INDUSTRIAL WATER TREATMENT ›› 2001, Vol. 21 ›› Issue (9): 21-23. doi: 10.11894/1005-829x.2001.21(9).21

Previous Articles     Next Articles

Researches on the organic harzardous effluent treatment by Fe0 -H2 O2oxidation

WANG Guangjian, CAO Changqing   

  1. Qingdao Institute of Chemical Technology, Qingdao 266042, China
  • Received:2001-03-10 Online:2001-09-20 Published:2010-10-01

用Fe0-H2O2氧化法处理高浓度有机废液研究

王广建, 曹长青   

  1. 青岛化工学院, 山东青岛 266042
  • 作者简介:王广建(1963- ),1989年毕业于天津大学研究生院硕士。电话:0532-5883836,E-mail:wgjnet@china.com

Abstract:

Fe0-H2O2oxidation is used to treat indust rial wastewater. Phenol(5000mg/L)and cresol(4000mg/L) are also used in the ex periments. The results show that after 330 minutes,the DOC conversion rate is 80% and yields less mire after neut ralization by using Fe0-H2O2 oxidation. But under the same ex perimental conditions, when traditional Fenton oxidation is used,the DOC conversion rate is only 60%. And if the conversion rate get shigher,there w ill be lots of mire yielded. Therefore,Fe0 -H2O2 oxidation is considered to be better than Fenton oxidation.

Key words: Fe0-H2O2 oxidation, conversion rate, organic waste

摘要:

提出了用于工业废水处理的Fe0-H2O2 氧化法,并用高浓度苯酚 (5000mg/L)和甲酚(4000mg/L)进行实验,结果表明Fe0-H2O2氧化法在 330min后,DOC转化率达80%,中和后污泥产生量少,而传统Fenton氧化法,同等实验条件下,DOC转化率仅为60%,而且后者再提高转化率,中和时伴随大量污泥产生,因此认为Fe0-H2O2氧化法优于Fenton氧化法。

关键词: Fe0-H2O2氧化法, 转化率, 有机废物

CLC Number: