Abstract:
The importance of steam condenser chemical supervision isexpounded.Familiar monitor indexesof condensing water are compared.It ispointed out that in the determination of steam,the using of Na + isvery sen-sitive,quick,convenient and suitable for the judgement of steam condenser leakage problems.It is,therefore,quantized.At the same time,based on the balance of substances,a simple formula hasbeen deduced.Good re-sultsare obtained in application
Key words:
sodiumions,
steam condenser,
condensing water,
leakage rate
摘要:
阐述了凝汽器化学监督的重要性,对常见的凝结水监测指标进行了比较,指出在水汽测定中Na+的测定灵敏、快速、简便,非常适合于判断凝汽器泄漏的问题,且可以使之量化。同时根据物料平衡,推导出其简易的应用公式,并在实际应用中取得了较好的结果。
关键词:
钠离子,
凝汽器,
凝结水,
泄漏率
CLC Number:
Fu Dongmiao, Huang Xiaochun. Determination of steam condenser leakage rate by using Na+ and its application[J]. INDUSTRIAL WATER TREATMENT, 2004, 24(1): 54-55.