INDUSTRIAL WATER TREATMENT ›› 2004, Vol. 24 ›› Issue (6): 50-51. doi: 10.11894/1005-829x.2004.24(6).50

Previous Articles     Next Articles

Determination of lead in water by atomic fluorescence spectrometry

Xie Yongjian   

  1. Zhaoqing City Water Supply Co., Zhaoqing 526020, China
  • Online:2004-06-20 Published:2010-10-01

水中铅的原子荧光光谱测定法

谢勇坚   

  1. 广东省肇庆市自来水公司, 广东肇庆 526020
  • 作者简介:谢勇坚(1967-),1989年毕业于广东省韶关卫生学校,工程师.电话:0758-2852014.

Abstract:

Atomic fluorescence spectrometric determination of lead in water is carried out. The results obtained show that linearity is good(the related average coefficient is 0.999 0 in standard curve 0.00 ~ 10.00 μg/L). The precision is better(the relative standard deviation is 0.96% ~ 3.52%). The accuracy and sensitivity are higher(the recovery rate is 90.3% ~ 108.4%, detection limit is 0.09 μg/L). It is a pretty good method for the determination of lead in water.

Key words: atomic fluorescence spectrometry, determination of lead, hydride generation

摘要:

采用原子荧光光谱法测定水中铅。实验结果表明,线性关系良好(在标准曲线质量浓度为0.00~10.00μg/L内,平均相关系数γ为0.9990),精密度较好(相对标准偏差为0.96%~3.52%),准确度、灵敏度较高(加标回收率为90.3%~108.4%,最低检出限为0.09μg/L),是测定水中铅的较好方法。

关键词: 原子荧光光谱法, 铅的测定, 氢化物发生